Applications
Leuze electronic
GS 754B
11
TNT
35/7-2
4
V
5.1.1
ASCII representation via RS 232 (P and M12 interfaces)
Figure 5.2:
Diameter determination - Detection of 1, 2 or 3 objects
)
Table 5.1:
ASCII representation, output modes 1 … 5
Example for xxx
:
123 (12.3mm)
5.1.2
Binary representation via RS 232 (P and M12 interfaces)
Due to the fast output of measurement values, only data for single-object detection can be
output in this output mode. The measurement values cannot be displayed on the screen
(see chapter 7.2.2).
1 object
2 objects
3 objects
Transmitter
Transmitter
Transmitter
Receiver
Receiver
Receiver
Parameter
ASCII output data via S1 and S2
Q,q
Single-object detection
Middle pos. : xxx Diameter: xxx
W,w
Detection of two objects
Middle pos. : xxx Diameter: xxx
Middle pos. : xxx Diameter: xxx
E,e
Detection of three objects
Middle pos. : xxx Diameter: xxx
Middle pos. : xxx Diameter: xxx
Middle pos. : xxx Diameter: xxx
1
2 1
3 2 1