Device configuration
Leuze electronic
GS 754B
15
TNT
35/7-2
4
V
6.3
Configuration of the measurement, analysis and output procedures
over interface P
The appropriate configuration is activated by entering ASCII characters. Letters may be
entered in either capital or lowercase form.
6.3.1
Configuration table for GS 754B
ASCII commands
Available for interface
Output mode
Object type
"!" - perforated objects
"?" - homogeneous objects
"%" - partially transparent,
translucent objects
1
output cycle approx. 3000ms output cycle approx. 700ms
serial and analog
2
output cycle approx. 1000ms output cycle approx. 250ms
serial and analog
3
output cycle approx. 500ms
output cycle approx. 130ms
serial and analog
4
output cycle approx. 250ms
output cycle approx. 70ms
serial and analog
5
output cycle approx. 100ms
output cycle approx. 35ms
serial and analog
6
reserved
reserved
7 (default)
output cycle approx. 12ms
output cycle approx. 3ms
serial and analog
Averaging
M,m
averaging across the specified output cycle period
serial and analog
A,a
output of individual measurement value (default)
serial and analog
Object number
Q,q
single-object measurement (default)
serial (only modes 1-5)
W,w
measurement of two objects
serial (only modes 1-5)
E,e
measurement of three objects
serial (only modes 1-5)
Evaluation process
=
diameter detection
serial and analog
-
edge detection (default)
serial and analog
Object type
!
perforated objects
serial and analog
?
homogeneous objects (default)
serial and analog
%
semi-transparent, translucent objects
serial and analog
Reset
R,r
reset with config. switching output (7,a,-,o,?)
reset with config. teach input (7,a,-,t,?)
serial and analog