PROFINET interface – basic configuration
Leuze electronic
BPS 348i
64
8.6.12 Module 10 – Velocity
Parameter
Rel.
Adr.
Data type Value range
De
-
fault
Measure
-
ment unit
Description
metr. Inch
Position value in the case of
error
0.0 …
0.1
Bit
0 … 1
1
-------------
Position value in the case of an error after the error
delay time elapses:
0: Last valid value
1: Zero
Suppress position status
0.2
Bit
0 … 1
1
-------------
Status bit (module 6 bit 0.7) in the case of an error:
0: OFF (status bit is set immediately)
1: ON (status bit is suppressed for the configured
error delay time)
Error delay (position)
0.3
Bit
0 … 1
1
-------------
Position value in the case of an error:
0: OFF (immediately the value of the
Position value
in the case of error
parameter)
1: ON (the last valid position value for the configured
error delay time)
Error delay time (position)
1 … 2
unsign
16 bit
10 … 4.000
50
1 ms
Errors that occur are suppressed for the configured
time, i.e., if no valid position value can be ascertained
in the configured time, the last valid position value is
always output. If the error persists after the time
elapses, the value of the
Position value in the case of
error
parameter is output.
Velocity in the case of error
3.0 …
3.1
Bit
0 … 1
1
-------------
Velocity value in the case of an error after the error
delay time elapses (velocity):
0: Last valid value is output
1: Zero is output
Suppress velocity status
3.2
Bit
0 … 1
1
-------------
Status bit (module 16 bit 0.0) in the case of an error:
0: OFF (status bit is set immediately)
1: ON (status bit is suppressed for the configured
error delay time)
Error delay (velocity)
3.3
Bit
0 … 1
1
-------------
Velocity in the case of an error:
0: OFF (immediately outputs the value of the
Velocity
in the case of error
parameter)
1: ON (outputs the last valid velocity for the config
-
ured error delay time)
Error delay time (velocity)
4 … 5
unsign
16 bit
10 … 4.000
50
1 ms
Errors that occur are suppressed for the configured
time, i.e., if no valid velocity can be ascertained in the
configured time, the last valid velocity is always out
-
put. If the error persists after the time elapses, the
value of the
Velocity in the case of error
parameter is
output.
Module ID: 1010 or submodule ID: 1
The module is used to output the current velocity in the desired resolution.
The unit (metric or inch) is set via module 1 (position value) and also applies to the velocity. If
module 1 is not configured, the value is output with the default unit of measurement (metric). The
sign of the velocity is dependent on the count direction selected in module 1. With the default
counting direction (positive), a positive velocity is output for movement towards larger tape val
-
ues. Movement towards smaller tape values results in negative velocities. Measurement value
preparation averages all velocity values calculated during the selected period (averaging) to yield
a velocity output value.
The module contains parameters (with parameter data length of 2 bytes) and input data (with
consistent input data length of 4 bytes), but no output data.