![Leuze electronic BPS 348i Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/leuze-electronic/bps-348i/bps-348i_manual_1883982054.webp)
PROFINET interface – basic configuration
Leuze electronic
BPS 348i
55
8.6.3 Module 1 – Position value
Module ID: 1001 or submodule ID: 1
Module for the output of the current position value. The module also includes the most important
parameters for formatting the output value.
The module contains parameters (with parameter data length of 6 bytes) and input data (with
consistent input data length of 4 bytes), but no output data.
Parameter
Rel.
Adr.
Data type Value range
De
-
fault
Measure
-
ment unit
Description
metr. Inch
Sign
0.0
Bit
0 … 1
0
-------------
Output mode of the sign. Affects position value and
velocity output:
0: Two's complement
1: Sign + quantity
Measurement unit
0.1
Bit
0 … 1
0
-------------
The selection of the measurement unit affects all val
-
ues with measurement units. The parameter applies
to all interfaces:
0: Metric (mm)
1: Inch (in)
Position resolution
0.2 …
0.4
Bit
4
mm
in/
100
Resolution of the position value. Affects only the
PROFINET output. The resolution has no effect on
the set parameter values such as offset or preset:
001 = 1: 0.001
010 = 2: 0.01
011 = 3: 0.1
100 = 4: 1
101 = 5: 10
110 = 6: Free resolution
Count direction
0.5
Bit
0
-------------
Count direction for position calculation or sign for
velocity calculation. The parameter affects all inter
-
faces:
0: Positive
1: Negative
Offset
1 …
4
sign
32 bit
-10.000.000 …
+10.000.000
0
mm
in/
100
Output value=measurement value+offset.
The parameter affects all interfaces.
Notice:
If a preset is active, this has priority over the offset.
Input data
Rel.
Adr.
Data type Value range
Init-
Value
Measure
-
ment unit
Description
metr. Inch
Position
0.0
sign
32 bit
-2.000.000.000
…
+2.000.000.000
0
scaled
Current position.
NOTICE
Convert numerical values when changing the unit of measurement!
If the unit of measurement is changed from metric to inch (or vice versa), previously entered numerical
values (e.g. for offset, preset, limit values etc.) are not automatically converted.
Example: Offset = 10000 mm – after changing from metric to inch: Offset = 10000 inch/100
Manually convert the numerical values when changing the unit of measurement.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]