![Leuze electronic BPS 348i Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/leuze-electronic/bps-348i/bps-348i_manual_1883982056.webp)
PROFINET interface – basic configuration
Leuze electronic
BPS 348i
57
8.6.6 Module 4 – Input/output I/O 1
Output data
Rel.
Adr.
Data type Value range
Init-
Value
Measure
-
ment unit
Description
metr. Inch
Teach Preset
0.0
Bit
0 … 1
---
-------------
Read in the preset value:
Transition 0 → 1: Teach Preset
Reset Preset
0.1
Bit
0 … 1
---
-------------
Preset value is deactivated:
Transition 0 → 1: Reset Preset
Preset value
1
sign
32 bit
-10.000.000 …
+10.000.000
---
-------------
New position value for a teach event via bit 0.0.
Module ID: 1004 or submodule ID: 1
This module is used to set the mode of operation of digital input/output I/O 1. The connection can
be used as either an input or an output.
The output is activated by various events in the device.
If used as an input, a device function is controlled by an external signal.
Alternatively, the connection can also be used decoupled from the device:
- If used as an input, the state of an external signal is transmitted to the control in the input data.
- If used as an output, the connection is operated via the output data.
The module contains parameters (with parameter data length of 4 bytes), input data (with input
data length of 1 byte) and output data (with output data length of 1 byte).
Parameter
Rel.
Adr.
Data type Value range
De
-
fault
Measure
-
ment unit
Description
metr. Inch
Function
0.0
Bit
0 … 1
1
-------------
Mode:
0: Input
1: Output
Activation
0.1
Bit
0 … 1
1
-------------
The parameter defines the level of the output at
which the
Output
event occurs.
0: LOW (output), transition 1 → 0
1: HIGH (output), transition 0 → 1
If the I/O is configured as an input, it responds edge-
triggered.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]