PROFINET interface – basic configuration
Leuze electronic
BPS 348i
54
8.6.2 DAP module – permanently defined parameters
On the PROFINET, parameters may be stored in modules or may be defined permanently in a PROFINET
participant. Depending on the configuration tool, the permanently defined but adjustable parameters are
called “common” parameters or device-specific parameters.
The common parameters must always be present. They are defined outside configuration modules and
are thus connected to the base module (DAP: Device Access Point) that is addressed via slot 0/subslot 0.
The following list contains the device parameters that are permanently defined in the BPS (DAP Slot 0/
Subslot 0) but are configurable. These parameters always exist and are available independent of the
modules.
Common parameters/device-specific parameters (DAP: Device Access Point):
M14
see page 67
Static velocity limit value 4
Switching type (P), Selection of direction (P), Velocity limit value 4 (P), Velocity
hysteresis 4 (P), Limit value 4 range start/range end (P)
M15
see page 68
Dynamic velocity limit value
Limit value control (P), Switching type (P), selection of direction (P), Velocity limit
value (P), Hysteresis (P), Limit value range start/range end (P)
M16
see page 69
Velocity state
Velocity measurement error (I), Velocity limit value 1 … 4 exceeded (I), Dynamic velocity
limit value exceeded (I), Movement status/direction (I), Velocity limit value status 1 … 4
active (I), Dynamic velocity limit value active (I)
M20
see page 70
Free resolution
Position (P), Velocity (P)
M21
see page 70
Distance to BCB
Distance (I)
M22
see page 71
Control and marker bar codes Reload (P), Transfer (P)
First/second/third character (I)
M23
see page 71
Tape value correction
Real length (P), Range start/end(P)
M24
see page 72
Read quality
Warning threshold/error threshold /read quality smoothing (P), Read quality (I)
Module
Module name
Module contents
(P) = Parameter, (O) = Output, (I) = Input
NOTICE
Set the tape selection!
Set the
Tape selection
parameter according to the used bar code tape grid.
Module ID: Profinet_DAP_001
Each PROFINET device must have a DAP module. The DAP module represents the communi
-
cation access point to the BPS.
The module contains device-specific parameters, but no input data and no output data.
Parameter
Rel.
Adr.
Data type Value range
De
-
fault
Measure
-
ment unit
Description
metr. Inch
Profile
0
Byte
2
2
--------------
Defines the used device profile.
Notice:
Currently, only the BPS profile is stored. Thus, no
selection is possible. Number of the activated profile.
2: BPS profile
Integration depth
1.0 …
1.4
Bit field
2 … 16
8
Measure
-
ments
Number of successive measurements that the BPS
uses for position determination.
Tape selection
1.5 …
1.6
Bit field
1: 30 mm BCB
2: 40 mm BCB
2
--------------
Changeover between bar code tape (BCB) with
30 mm grid and 40 mm grid.