![Leuze electronic BPS 348i Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/leuze-electronic/bps-348i/bps-348i_manual_1883982049.webp)
PROFINET interface – basic configuration
Leuze electronic
BPS 348i
50
8.3
Conformance Classes
PROFINET devices are categorized into conformance classes to simplify the evaluation and selection of
the devices for the users.
The BPS corresponds to Conformance Class B (CC-B) and can use an existing Ethernet network infra
-
structure.
The BPS supports the following features:
• Cyclical RT communication
• Acyclic TCP/IP communication
• Alarms/diagnostics
• Automatic address assignment
• I&M0 functionality
• Neighborhood detection basic functionality
• FAST Ethernet 100 Base-TX/FX
• Convenient device exchange without engineering tools
• SNMP support
8.4
Starting the device
To start the BPS:
Connect the supply voltage.
The BPS starts up and, for devices with a display, a device status is displayed.
Configure the BPS, e.g., for a Siemens SIMATIC-S7 control.
Assign the BPS its individual device name and name the device.
8.5
Configuring for the Siemens SIMATIC-S7 control
The following steps are necessary for commissioning:
• Preparing the control system (S7 PLC)
• Installation of the GSDML file
• Hardware configuration of the S7 PLC
• Transmission of the PROFINET configuration to the controller (S7 PLC)
• Device naming
• Check device name
Proceed as follows:
To prepare the control (S7 PLC):
- Assign an IP address to the IO controller (S7 PLC)
- Prepare the control system for consistent data transmission.
Install the GSDML file for the subsequent configuration of the BPS.
You can find the GSDML file at
Leuze website
> Products > Measuring Sensors
> Sensors for Positioning > BPS 300i > (Name of the BPS) > Tab Downloads > Software/driver
> GSDML file.
NOTICE
Must be observed!
For the Siemens SIMATIC-S7 control, you need at least SIMATIC Manager version 5.4 + service pack
5 (V5.4+SP5).