85
MENU 11: SERIAL LINK - DRIVE CHARACTERISTICS - MISCELLANEOUS
LEROY-SOMER
11.3 - Explanation of parameters in
menu 11
11.01, 11.02, 11.03, 11.04, 11.05, 11.06, 11.07, 11.08, 11.09, 11.10, 11.11, 11.12, 11.13, 11.14, 11.15, 11.16, 11.17, 11.18, 11.19, 11.20
to
: Menu 0 set-up
Adjustment range :
0
0
.
.
0
0
0
0
to
2
2
1
1
.
.
5
5
1
1
Factory settings
: See table below.
These parameters are used, in order, to determine
parameters
4
4
6
6
to
6
6
5
5
in menu 0. These parameters are
independent of the preset configuration.
11.21
:Customer unit
Adjustment range : 0 to 9.999
Factory setting
: 1.00
This is a multiplication coefficient applied to the motor speed
for expressing the speed in a unit defined by the user
(see
5
5
.
.
3
3
4
4
).
Example: to obtain a reading in m/min for an application
where the product is moving 200 mm for each motor
revolution ==>
1
1
1
1
.
.
2
2
1
1
= 0.2.
11.22
:Unit displayed at power-up
Adjustment range : 0 to 2
Factory setting
: 0
0 (Spd): On power-up, the speed is displayed.
The unit depends on the setting of 5
5
.
.
3
3
4
4
(frequency in Hz,
speed in rpm or a unit defined by the user).
1 (Load):
On power-up, the load is displayed.
The unit displayed depends on the setting of
4
4
.
.
2
2
1
1
(motor
load as a % or output current in A).
2 (SP.Ld):
Displays the speed and the load alternately, or the
current. The display time of each value can be configured in
1
1
1
1
.
.
4
4
7
7
.
11.23
:Serial address
Adjustment range : 0 to 247
Factory setting
: 1
Used to define the drive address in the case of control or
supervision via the serial link. Avoid values containing a zero
as they are used to address the drive sets.
11.24
:Serial mode
Adjustment range : 0 or 1
Protocol used for communication via the serial link.
0 :
LSnt:
LS Net protocol.
1 : rtu:
Modbus RTU protocol
.
11.25
:Baud rate
Adjustment range : 0 to 9
Factory setting
: 6
Used to select the data transfer speed in Modbus RTU.
Note :
If CT Comms Cable is used, the baud rate is limited to
38400 bauds.
11.26
:Minimum comms transmit delay
Adjustment range : 0 to 250 ms
Factory setting
: 2 ms
As the serial link is 2-wire type, Rx is connected to Tx and Rx\
to Tx\. A communication fault may occur if the receiver is
responding to a request before the sender has had time to
switch. Parameter
1
1
1
1
.
.
2
2
6
6
is used to introduce a time between
reception and the data feedback. After transmission of a
request, the drive needs 1.5 ms before receiving the next
command. The adjustment is made in 2 ms intervals.
11.27
:Modbus RTU frame format
Adjustment range : 0 to 3
Factory setting
: 0
0 (OP.2S): No parity, 2 stop bits.
1 (OP.1S):
No parity, 1 stop bit.
2 (eP.1S):
Even parity, 1 stop bit.
3 (oP.1S):
Odd parity, 1 stop bit.
11.28
:Not used
11.29
:Software version
Adjustment range : 1.00 to 9.99
Indicates the drive software version
11.30
:User security code
Adjustment range : 0 to 9999
Factory setting
: 0
If this parameter is other than 0 and
1
1
1
1
.
.
4
4
4
4
is set to 2 (Loc),
no parameter modification can take place. To modify a
parameter, the user must enter a code equivalent to the value
of
1
1
1
1
.
.
3
3
0
0
.
Parameter
Default value
Menu 0 destination
1
1
1
1
.
.
0
0
1
1
6
6
.
.
0
0
4
4
4
4
6
6
1
1
1
1
.
.
0
0
2
2
8
8
.
.
1
1
0
0
4
4
7
7
1
1
1
1
.
.
0
0
3
3
7
7
.
.
1
1
5
5
4
4
8
8
1
1
1
1
.
.
0
0
4
4
7
7
.
.
3
3
3
3
4
4
9
9
1
1
1
1
.
.
0
0
5
5
8
8
.
.
4
4
1
1
5
5
0
0
1
1
1
1
.
.
0
0
6
6
1
1
.
.
0
0
5
5
5
5
1
1
1
1
1
1
.
.
0
0
7
7
1
1
.
.
1
1
0
0
5
5
2
2
1
1
1
1
.
.
0
0
8
8
1
1
.
.
2
2
9
9
5
5
3
3
1
1
1
1
.
.
0
0
9
9
1
1
.
.
3
3
0
0
5
5
4
4
1
1
1
1
.
.
1
1
0
0
2
2
.
.
0
0
4
4
5
5
5
5
1
1
1
1
.
.
1
1
1
1
2
2
.
.
0
0
6
6
5
5
6
6
1
1
1
1
.
.
1
1
2
2
2
2
.
.
0
0
7
7
5
5
7
7
1
1
1
1
.
.
1
1
3
3
6
6
.
.
0
0
1
1
5
5
8
8
1
1
1
1
.
.
1
1
4
4
6
6
.
.
0
0
9
9
5
5
9
9
1
1
1
1
.
.
1
1
5
5
5
5
.
.
1
1
8
8
6
6
0
0
1
1
1
1
.
.
1
1
6
6
5
5
.
.
0
0
6
6
6
6
1
1
1
1
1
1
.
.
1
1
7
7
5
5
.
.
1
1
1
1
6
6
2
2
1
1
1
1
.
.
1
1
8
8
5
5
.
.
1
1
2
2
6
6
3
3
1
1
1
1
.
.
1
1
9
9
1
1
1
1
.
.
4
4
2
2
6
6
4
4
1
1
1
1
.
.
2
2
0
0
1
1
1
1
.
.
4
4
3
3
6
6
5
5
1
1
1
1
.
.
0
0
1
1
1
1
1
1
.
.
2
2
0
0
1
1
1
1
.
.
2
2
1
1
1
1
1
1
.
.
2
2
2
2
1
1
1
1
.
.
2
2
3
3
Speed feedback
Display
1
1
1
1
.
.
2
2
5
5
300
0.3
0
600
0.6
1
1200
1.2
2
2400
2.4
3
4800
4.8
4
9600
9.6
5
19200
19.2
6
38400
38.4
7
57600
57.6
8
115200
115.2
9
1
1
1
1
.
.
2
2
4
4
1
1
1
1
.
.
2
2
5
5
1
1
1
1
.
.
2
2
6
6
1
1
1
1
.
.
2
2
7
7
1
1
1
1
.
.
2
2
8
8
1
1
1
1
.
.
2
2
9
9
1
1
1
1
.
.
3
3
0
0
Содержание PROXIDRIVE
Страница 8: ...8 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive LEROY SOMER 3756 en 05 2004 b Notes ...
Страница 24: ...24 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive MENU 2 RAMPS LEROY SOMER 3756 en 05 2004 b Notes ...
Страница 104: ...104 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive MENU 15 RESERVED LEROY SOMER 3756 en 05 2004 b Notes ...
Страница 121: ...121 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive OPERATION WITH MODBUS RTU LEROY SOMER 3756 en 05 2004 b ...
Страница 122: ...122 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive OPERATION WITH MODBUS RTU LEROY SOMER 3756 en 05 2004 b ...
Страница 123: ......
Страница 124: ......