MENU 3: FREQUENCY THRESHOLDS - ENCODER OPTION
LEROY-SOMER
3.44
:Drive encoder reference scaling
Adjustment range : 0 to 2.0000
Factory setting
: 1.0000
Used for scaling the numerical reference to be converted into
pulses.
3.45
:Drive encoder reference
Adjustment range : 0 to 100% (
); ± 100% (
)
Indicates the value of the numerical reference resulting from
conversion of the pulse signal.
3.46
:Drive encoder reference destination
Adjustment range :
0
0
.
.
0
0
0
0
to
2
2
1
1
.
.
5
5
1
1
Factory setting
:
0
0
.
.
0
0
0
0
Used to select the destination of the numerical reference
resulting from conversion of the pulse signal. Only "non-bit"
type parameters can be programmed. If an unsuitable
parameter is selected,
3
3
.
.
4
4
6
6
will be frozen at 0.
3.47, 3.48, 3.49, 3.50
to
: Not used
3.51
:Vmin alarm threshold
Adjustment range : 0 to 500 rpm
Factory setting
: 90 rpm
Triggers an alarm
1
1
0
0
.
.
5
5
1
1
when the motor speed
(
5
5
.
.
0
0
4
4
) < Vmin (
1
1
.
.
0
0
7
7
) +
3
3
.
.
5
5
1
1
in open loop mode or speed
(
3
3
.
.
0
0
2
2
) +
3
3
.
.
5
5
1
1
in closed loop mode.
3.52
:Vmax alarm threshold
Adjustment range : 0 to 500 rpm
Factory setting
: 90 rpm
Triggers an alarm (
1
1
0
0
.
.
5
5
2
2
) when the motor speed
(
5
5
.
.
0
0
4
4
) > Vmax (
1
1
.
.
0
0
6
6
) -
3
3
.
.
5
5
2
2
in open loop mode or speed
(
3
3
.
.
0
0
2
2
) -
3
3
.
.
5
5
2
2
in closed loop mode.
3.53, 3.54, 3.55, 3.56, 3.57, 3.58, 3.59, 3.60
to
: Not used
3.61
:Drive encoder source
Adjustment range :
0
0
.
.
0
0
0
0
to
2
2
1
1
.
.
5
5
1
1
Factory setting
:
0
0
.
.
0
0
0
0
Used to select the source of pulses. Only "bit" type
parameters can be programmed. If an unsuitable parameter
is selected,
3
3
.
.
6
6
1
1
will be frozen at 0.
Note:
Only use inputs ADI1, ADI2, DIO1, DI2 and DI3 as the
drive encoder source. The maximum input frequency should
be 5 kHz. If the input frequency is more than 5 kHz, use an
encoder feedback option, and set
3
3
.
.
6
6
7
7
to 1 (EnCd).
3.62
:Drive encoder frequency
Adjustment range : 0 to 5000 Hz
Drive encoder frequency which will be converted to a
numerical reference.
Example of application:
Pulses from an inductive sensor connected on a digital input
are converted into a reference which is assigned to the speed
reference.
3.63
:Maximum drive output reference
Adjustment range : 0 to 32000
Factory setting
: 5000
Adjusts the pulse frequency which should correspond to
100% of the original numerical value.
Function not available in version V2.10.
3.64
:Drive output reference scaling
Adjustment range : 0 to 2.0000
Factory setting
: 1.0000
Used for scaling the reference from the drive encoder.
Function not available in version V2.10.
3.65
:Drive output reference
Adjustment range : 0 to 100%
Indicates the analog reference value.
Function not available in version V2.10.
3.66
:Drive output destination
Adjustment range :
0
0
.
.
0
0
0
0
to
2
2
1
1
.
.
5
5
1
1
Factory setting
:
0
0
.
.
0
0
0
0
Used to select the destination for the numerical reference
which will be used to generate pulses. Only "non-bit"
parameters can be programmed. If an unsuitable parameter
is selected,
3
3
.
.
6
6
6
6
will be frozen at 0.
Function not available in version V2.10.
3.67
:Reference select (
)
Adjustment range : 0 or 1
Factory setting
: 0
0 (Freq): An analog reference is generated from a
frequency signal.
1 (Encd):
The encoder signal is used to generate an analog
reference (eg: speed reference).
3.68, 3.69, 3.70
to
: Not used
3.71
:Drive output reference source
Adjustment range :
0
0
.
.
0
0
0
0
to
2
2
1
1
.
.
5
5
1
1
Factory setting
:
0
0
.
.
0
0
0
0
Used to select the source of the numerical reference which
will be converted into pulses.
Function not available in version V2.10.
3.72
:Drive output period
Adjustment range : 0.5 to 3200.0s
Drive output period resulting from conversion of the numerical
reference.
Example of application:
A potentiometer connected to an analog input generates a
period which is converted into pulses whose frequency is
proportional to the reference. The pulses are assigned to the
run command.
Function not available in version V2.10.
3
3
.
.
4
4
4
4
3
3
.
.
4
4
5
5
3
3
.
.
4
4
6
6
3
3
.
.
4
4
7
7
3
3
.
.
5
5
0
0
3
3
.
.
5
5
1
1
3
3
.
.
5
5
2
2
3
3
.
.
5
5
3
3
3
3
.
.
6
6
0
0
3
3
.
.
6
6
1
1
3
3
.
.
6
6
2
2
3
3
.
.
6
6
3
3
3
3
.
.
6
6
4
4
3
3
.
.
6
6
5
5
3
3
.
.
6
6
6
6
3
3
.
.
6
6
7
7
3
3
.
.
6
6
8
8
3
3
.
.
7
7
0
0
3
3
.
.
7
7
1
1
3
3
.
.
7
7
2
2
Содержание PROXIDRIVE
Страница 8: ...8 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive LEROY SOMER 3756 en 05 2004 b Notes ...
Страница 24: ...24 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive MENU 2 RAMPS LEROY SOMER 3756 en 05 2004 b Notes ...
Страница 104: ...104 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive MENU 15 RESERVED LEROY SOMER 3756 en 05 2004 b Notes ...
Страница 121: ...121 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive OPERATION WITH MODBUS RTU LEROY SOMER 3756 en 05 2004 b ...
Страница 122: ...122 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive OPERATION WITH MODBUS RTU LEROY SOMER 3756 en 05 2004 b ...
Страница 123: ......
Страница 124: ......