66
MENU 8: ASSIGNMENT OF DIGITAL INPUTS AND OUTPUTS
LEROY-SOMER
8.20
:Digital I/O read word
Adjustment range : 0 to 511
This parameter is used to determine the state of the I/O with
a single read operation.
Each bit of this word represents the state of parameters
8
8
.
.
0
0
1
1
to
8
8
.
.
0
0
9
9
.
8.21
: DIO1 input destination/output source
Adjustment range :
0
0
.
.
0
0
0
0
to
2
2
1
1
.
.
5
5
1
1
Factory setting
:
1
1
0
0
.
.
0
0
3
3
Zero frequency
This parameter is used to select the DIO1 input destination or
output source.
Any unprotected "bit" type parameter can be assigned.
If an unsuitable parameter is addressed to an input or output,
no assignment is taken into account.
8.22
: DI2 input destination
Adjustment range :
0
0
.
.
0
0
0
0
to
2
2
1
1
.
.
5
5
1
1
Factory setting
:
6
6
.
.
3
3
0
0
Run FWD/Stop
This parameter is used to select the destination of input DI2.
Any unprotected "bit" type parameter can be assigned to the
input.
If an unsuitable parameter is addressed to an input or output,
no assignment is taken into account.
8.23
:DI3 input destination
Adjustment range :
0
0
.
.
0
0
0
0
to
2
2
1
1
.
.
5
5
1
1
Factory setting
:
6
6
.
.
3
3
2
2
Run REV/Stop
This parameter is used to select the destination of input DI3.
Any unprotected "bit" type parameter can be assigned to the
input.
If an unsuitable parameter is addressed to an input or output,
no assignment is taken into account.
Note:
In pulsed mode
6
6
.
.
0
0
4
4
= 1 (Puls),
8
8
.
.
2
2
3
3
is frozen at
6
6
.
.
3
3
9
9
. To unfreeze it, you need to modify the value of
6
6
.
.
0
0
4
4
.
8.24
:DI4 input destination
Adjustment range :
0
0
.
.
0
0
0
0
to
2
2
1
1
.
.
5
5
1
1
Factory setting
:
1
1
.
.
4
4
1
1
: Selection of analog reference
1 or 2
This parameter is used to select the destination of input DI4.
Any unprotected "bit" type parameter can be assigned to the
input.
If an unsuitable parameter is addressed to an input or output,
no assignment is taken into account.
8.25, 8.26
and
:Not used
8.27
:Relay source
Adjustment range :
0
0
.
.
0
0
0
0
to
2
2
1
1
.
.
5
5
1
1
Factory setting
:
1
1
0
0
.
.
0
0
1
1
Drive ready
This parameter is used to select the source for the output
relay.
Any unprotected "bit" type parameter can be assigned.
If an unsuitable parameter is addressed to an input or output,
no assignment is taken into account.
CAUTION:
When the safety function is enabled 8
8
.
.
1
1
0
0
= 1 (sEcu), the
value of 8
8
.
.
2
2
7
7
is fixed at 1
1
0
0
.
.
0
0
1
1
, and cannot be modified.
8.28, 8.29, 8.30
to
: Not used
8.31
:DIO1 input or output select
Adjustment range : 0 or 1
Factory setting
: 1
Used to configure terminal DIO1 as an input or output.
0 (In):
Terminal configured as an input.
1 (Out): Terminal configured as an output.
8.32, 8.33, 8.34, 8.35, 8.36, 8.37, 8.38, 8.39, 8.40
to
: Not used
8.41
:DIO1 control
Adjustment range : 0 to 9
Factory setting
: 0
This parameter is used to assign the DIO1 function quickly.
Depending on the value of
8
8
.
.
4
4
1
1
,
8
8
.
.
2
2
1
1
and
8
8
.
.
3
3
1
1
are
automatically configured according to the table below.
8.42, 8.43, 8.44, 8.45, 8.46, 8.47, 8.48, 8.49, 8.50, 8.51, 8.52, 8.53, 8.54, 8.55, 8.56, 8.57, 8.58, 8.59, 8.60
to
: Not used
Bit
0
1
2
3
4
5
6
7
8
State 8
8
.
.
0
0
1
1
8
8
.
.
0
0
2
2
8
8
.
.
0
0
3
3
8
8
.
.
0
0
4
4
8
8
.
.
6
6
1
1
8
8
.
.
6
6
2
2
8
8
.
.
0
0
7
7
8
8
.
.
6
6
3
3
8
8
.
.
0
0
9
9
8
8
.
.
2
2
0
0
8
8
.
.
2
2
1
1
8
8
.
.
2
2
2
2
8
8
.
.
2
2
3
3
8
8
.
.
2
2
4
4
8
8
.
.
2
2
5
5
8
8
.
.
2
2
6
6
Value
Mnemonic
DIO1 function
Value
Value
of 8
8
.
.
2
2
1
1
of 8
8
.
.
3
3
1
1
0
n = 0
Zero speed
output
1
1
0
0
.
.
0
0
3
3
1
1
At.SP
Reference
reached output
1
1
0
0
.
.
0
0
6
6
1
2
Lo.SP
Minimum
speed output
1
1
0
0
.
.
0
0
4
4
1
3
At.Ld
Rated load
reached output
1
1
0
0
.
.
0
0
8
8
1
4
act
Drive output
active
1
1
0
0
.
.
0
0
2
2
1
5
alar
Drive general
alarm output
1
1
0
0
.
.
1
1
9
9
1
6
I.Lt
Current limit
output
1
1
0
0
.
.
0
0
9
9
1
7
JoG
Jogging input
6
6
.
.
3
3
1
1
0
8
rESE
Reset input
1
1
0
0
.
.
3
3
3
3
0
9
Adv
Any
assignment
0
0
.
.
0
0
0
0
1
8
8
.
.
2
2
7
7
8
8
.
.
2
2
8
8
8
8
.
.
3
3
0
0
8
8
.
.
3
3
1
1
8
8
.
.
3
3
2
2
8
8
.
.
4
4
0
0
8
8
.
.
4
4
1
1
8
8
.
.
4
4
2
2
8
8
.
.
6
6
0
0
Содержание PROXIDRIVE
Страница 8: ...8 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive LEROY SOMER 3756 en 05 2004 b Notes ...
Страница 24: ...24 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive MENU 2 RAMPS LEROY SOMER 3756 en 05 2004 b Notes ...
Страница 104: ...104 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive MENU 15 RESERVED LEROY SOMER 3756 en 05 2004 b Notes ...
Страница 121: ...121 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive OPERATION WITH MODBUS RTU LEROY SOMER 3756 en 05 2004 b ...
Страница 122: ...122 ADVANCED USER GUIDE PROXIDRIVE IP66 variable speed drive OPERATION WITH MODBUS RTU LEROY SOMER 3756 en 05 2004 b ...
Страница 123: ......
Страница 124: ......