Electrical installation
Control terminals
l
34
LDEDS−CCU210B EN 4.0
X41 − digital input DIN2 / digital output DOUT1
Pin
Signal
Description
Data
Connector: socket, 4−pole, M12
1
+24V DC
Supply
HIGH
+16 .... +26.5 V DC
2
DOUT1
Digital output 1
LOW
0 ... +4 V
3
GND
Reference potential
4 mA
Current per input for 24 V DC
4
DIN2
Digital input 2
max.
200 mA
Permissible current loading per
output
If inductive loads are being
switched, freewheeling diodes
are required. Place the diodes
as close to the inductor load as
possible!
X42 − digital inputs DIN1/DIN8
Pin
Signal
Description
Data
Connector: socket, 4−pole, M12
1
+24V DC
Supply
HIGH
+16 .... +26.5 V DC
2
DIN8
Digital input 8
LOW
0 ... +4 V
3
GND
Reference potential
4 mA
Current per input for 24 V DC
4
DIN1
Digital input 1
Control terminals for devices in a power range of 0.75 kW
X43 − digital inputs DIN1/DIN2
Pin
Signal
Description
Data
Connector: socket, 4−pole, M12
1
+24V DC
Supply
HIGH
+16 .... +26.5 V DC
2
DIN1
Digital input 1
LOW
0 ... +4 V
3
GND
Reference potential
4 mA
Current per input for 24 V DC
4
DIN2
Digital input 2
X44 − digital inputs DIN3/DOUT1 − DIN4
Pin
Signal
Description
Data
Connector: socket, 4−pole, M12
1
+24V DC
Supply
HIGH
+16 .... +26.5 V DC
2
1)
DIN3
Digital input 3
LOW
0 ... +4 V
DOUT1
Digital output 1
4 mA
Current per input for 24 V DC
3
GND
Reference potential
max.
200 mA
Permissible current loading per
output
If inductive loads are being
switched, a spark suppressor
must be used at the output!
4
DIN4
Digital input 4
1)
DIN/DOUT cannot be used at the same time!