Appendix
Code table
l
104
LDEDS−CCU210B EN 4.0
Description
Possible settings
Code
Selection
Lenze
Byte
<
ñò
No.
C0434
Deceleration ramp Vx
ð
V0 for ...
^
1 RW
EXT
4
50
1
{Hz/s}
255 ... Stop 1
2
50
... Stop 2
3
50
... Stop 3
4
50
... Stop 4
C0440
Configuration of function ...
^
1 RW
EXT
4
3
... Frequency limitation 1
2
3
... Frequency limitation 2
3
3
... Frequency limitation 3
4
3
... Frequency limitation 4
Possible values
1
Frequency limitation only active in
the case of CW rotation
2
Frequency limitation only active in
the case of CCW rotation
3
Frequency limitation active in the
case of CW and CCW rotation
C0441
Drive frequency for ...
^
1 RW
EXT
4
0
0
{Hz}
120.0 ... Frequency limitation 1 (VL1)
2
0
... Frequency limitation 2 (VL2)
3
0
... Frequency limitation 3 (VL3)
4
0
... Frequency limitation 4 (VL4)
C0442
delay time:
acceleration VLx
ð
Vx after
deactivation of ...
^
1 RW
EXT
4
0
0
{ms}
20000 ... Frequency limitation 1
2
0
... Frequency limitation 2
3
0
... Frequency limitation 3
4
0
... Frequency limitation 4
C0443
delay time:
start of deceleration ramp Vx
ð
VLx
after command ...
^
1 RW
EXT
4
0
0
{ms}
20000 ... Frequency limitation 1
2
0
... Frequency limitation 2
3
0
... Frequency limitation 3
4
0
... Frequency limitation 4
C0444
Deceleration ramp Vx
ð
VLx for ...
^
1 RW
EXT
4
50
1
{Hz/s}
255 ... Frequency limitation 1
2
50
... Frequency limitation 2
3
50
... Frequency limitation 3
4
50
... Frequency limitation 4
C0450
RW
EXT
4
0
"Open brake" function:
configuration
^
0
Brake opens immediately
Brake opens if C0410/15 = HIGH
1
Brake opens with delay
Brake opens if C0410/15 = HIGH
and drive frequency = 0 Hz
Содержание LDEC Series
Страница 2: ...0Fig 0Tab 0 ...
Страница 24: ...Mechanical installation Dimensions 5 l 24 LDEDS CCU210B EN 4 0 5 2 Dimensions Power 0 75 kW CCU210_002H ...
Страница 25: ...Mechanical installation Dimensions 5 l 25 LDEDS CCU210B EN 4 0 Power 1 5 kW CCU210_002B ...
Страница 26: ...Mechanical installation Dimensions 5 l 26 LDEDS CCU210B EN 4 0 Power 2 2 kW CCU210_002_2_2kW ...