Appendix
Code table
l
88
LDEDS−CCU210B EN 4.0
Description
Possible settings
Code
Selection
Lenze
Byte
<
ñò
No.
C0011
Drive frequency for ...
^
1 RW
EXT
4
0.0
0.0
{Hz}
120.0 ... V1
2
0.0
... V2
3
0.0
... V3
4
0.0
... V4
5
0.0
... V5
6
0.0
... V6
7
0.0
... V7
8
0.0
... V8
C0012
Acceleration time for ...
^
1 RW
EXT
4
50
1
{Hz/s}
255 ... V1
2
50
... V2
3
50
... V3
4
50
... V4
5
50
... V5
6
50
... V6
7
50
... V7
8
50
... V8
C0013
Deceleration time for ...
^
1 RW
EXT
4
50
1
{Hz/s}
255 ... V1
2
50
... V2
3
50
... V3
4
50
... V4
5
50
... V5
6
50
... V6
7
50
... V7
8
50
... V8
C0014
RW
EXT
4
80
Deceleration time for quick stop
functions:
l
On/Off switch
l
Error
l
SensoPart trip−out
^
1
{Hz/s}
255
C0015
RW
EXT
4
0
Operating mode
^
0
V/f characteristic control
1
Reserved
2
Reserved
C0016
RW
EXT
4
400
Mains voltage
^
0
{V}
480
C0017
RW
EXT
4
0
Mains frequency
^
0
50 Hz
1
60 Hz