18
EDBSV571 EN 1.0
EN
Commissioning
Display
INDICATING LEDs (on 4-character display)
FWD
FWD LED: Indicate the present rotation direction is forward. Refer to ROTATION
description above.
REV
REV LED: Indicate the present rotation direction is reverse. Refer to ROTATION
description above.
AUTO
AUTO LED: Indicates that the drive has been put into Auto mode from one of the
TB13 inputs (P121…P124 set to 1…7). Indicates that PID mode is active (if PID mode is
enabled). Indicates that sequencer mode is active (if sequencer mode is enabled).
RUN
RUN LED: Indicates that the drive is running.
p q
LED: Indicates that the
p q
are the active reference.
NOTE
If the keypad is selected as the auto reference (P121…P124 is 6) and the
corresponding TB-13 input is closed, the AUTO LED and
p q
LEDs will
both be on.
4.2
Drive Display and Modes of Operation
Speed Mode Display
In the standard mode of operation, the drive frequency output is set directly by the selected reference
(keypad, analog reference, etc.). In this mode, the drive display will show the drive’s output frequency.
PID Mode Display
When the PID mode is enabled and active, the normal run display shows the actual PID setpoint. When PID
mode is not active, the display returns to showing the drive’s output frequency.
Torque Mode Display
When the drive is operating in Vector Torque mode, the normal run display shows the drive’s output
frequency.
Alternate (Run-Screen) Display
When P179 (Run Screen Display) is set to a value other than 0, one of the diagnostic parameters (P501…
P599) is displayed. Example: if P179 is set to 1, then diagnostic parameter P501 (Software version) is
displayed. If P179 =2, then P502 (Drive ID) is displayed.