Code list
Parameter
C0001
Designation
Operating mode
Data type: INTEGER_32
Index: 24574
dec
= 5FFE
hex
Selection of the operating mode (control)
Selection list
(Lenze setting printed in bold)
Information
0 System bus (CAN) control word
1 Control via dig. inputs
2 Control word via automation
interface (AIF)
Parameter
C0002
Designation
Load Lenze setting
Data type: INTEGER_32
Index: 24573
dec
= 5FFD
hex
Note:
The Lenze setting can only be loaded if the controller is inhibited.
Selection list
(Lenze setting printed in bold)
Information
0 Load Lenze setting
1 Loading executed
Parameter
C0003
Designation
Save parameter set
Data type: UNSIGNED_32
Index: 24572
dec
= 5FFC
hex
Setting for saving the parameter set
Selection list
(Lenze setting printed in bold)
Information
0 No response
1 Save parameter set
Parameter
C0004
Designation
Selection of XT keypad status display
Data type: INTEGER_32
Index: 24571
dec
= 5FFB
hex
The XT keypad displays the selected code in the operating level if no other status messages from C0183 are
active.
l
Example: 53 = C0053 (DC−bus voltage)
Setting range
(min. value | unit | max. value)
Lenze setting
0
989
53
Parameter
C0009
Designation
LECOM device address
Data type: INTEGER_32
Index: 24566
dec
= 5FF6
hex
Entry of the device address for operation via AIF interface
Communication modules on AIF interface:
l
LECOM−A/B/LI 2102
l
PROFIBUS−DP 2133
Setting range
(min. value | unit | max. value)
Lenze setting
0
99
1