Diagnostics
Advanced diagnostics via diagnostics PDO (CAN2_OUT)
128
EDBCSXE040 EN 6.0
Size
Description
Value
C0390/1 ... 8
8
Internal error bits:
l
Bit 0 = 1: An Ixt overload has occurred.
l
Bit 1 = 1: The internal brake resistor is overloaded.
l
Bit 2 = 1: The external temperature contact is open.
l
Bit 3 = 1: A short circuit of the brake IGBT has occurred.
l
Bit 4 = 1: An LP0 error has occurred.
l
Bit 5 = 1: An LP1 error has occurred.
l
Bit 6 = 1: No short−circuit braking possible.
l
Bit 7 = 1: A U15 error has occurred (2 monitoring cycles below 17 V).
l
Bit 8 = 1: The 24V supply was lower than the 17V monitoring threshold.
l
Bit 9 ... 15: Not assigned.