Configuration
8
76
EDBCSXE040 EN 6.0
8
Configuration
The drive system can be adapted to your application by configuring the power supply
module. These interfaces can be used to configure the power supply module:
ƒ
X1 ˘ AIF (automation interface)
– For the connection of the keypad XT or communication modules (
serves to access the codes.
ƒ
X4 ˘ System bus interface (CAN)
– PC interface/HMI for parameter setting and diagnostics (e.g. with the Lenze
parameter setting and operating program "Global Drive Control")
or
– Interface to a decentralised I/O system
X4
4
5
X4
X14
X4
X14
X4
X14
Systembus (CAN)
MotionBus (CAN)
Y Z
y
z
T V
S U
d
A
B
b
c
p
SHPRG
Para
Code
Menu
0050
00
50.00_Hz
M C T R L- N O U T
X1
X1
X4
X14
X1
X1
0
1
3
X1
2
ECSXA028
Fig. 8−1
Example: Wiring of the MotionBus (CAN) and system bus (CAN)
Keypad XT or another communication module
PC/laptop or HMI
Decentralised I/O system
Higher−level host system / MotionBus control
ECSxE... power supply module
ECSxS/P/M/A... axis module