Configuration
Configuring system bus (CAN)
Assignment of the control word
105
EDBCSXE040 EN 6.0
8.2.9
Assignment of the control word
Control word to the power supply module (display in C0130)
Byte
Bit
Designation
Meaning
LOW
0
STE_TOGGLE
Toggle bit: Bit state change as a "sign of life" of the
control
1
STE_RESET
0:
1:
Reset fault message
Active fault message
2
STE_KSB
0:
1:
No short−circuit braking (KSB)
Carry out short−circuit braking (KSB)
3
STE_REGLERFREIGABE
0:
1:
X6/DO1 always LOW
X6/DO1 is HIGH if the power supply module is ready for
operation and the input X6/DI2 is HIGH.
4
Free
...
7
HIGH
8
Reserved
...
10
11
Free
...
15