Appendix
Code table
400
EDBCSXS064 EN 4.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C2120 AIF: Control
0
AIF−CAN: control word
0
{1}
255 Binary interpretation reflects bit
states
0
No command
Note:
The MSB (bit 7) of the
control word automatically
changes its state with every
access to the code. Observe this
when interpreting the data!
1
Read XCAN codes + reinitialisation
2
Read XCAN code
10
Read XCAN C2356/1 ... 4
11
Read XCAN C2357
12
Read XCAN C2375
13
Read XCAN C2376 ... C2378
14
Read XCAN C2382
255
Not assigned
C2121 AIF:State
AIF status
More detailed information can
be found in the documentation
of the plugged−in fieldbus
module.
Read only
1
{1}
255 Binary interpretation reflects bit
states.
Bit 0
XCAN1_IN monitoring time
Bit 1
XCAN2_IN monitoring time
Bit2
XCAN3_IN monitoring time
Bit3
XCAN bus off
Bit4
XCAN operational
Bit5
XCAN pre−operational
Bit 6
XCAN warning
Bit 7
Assigned internally
C2130 FileNameAdd
Da
Symbolic data name
Information on the additional
data that have been transmitted
together with the application
program.
Only display
C2131 Type AddData
Specification identification of the data
C2132 VersionAddDa
ta
Data version
C2133 TimeStamp
Time stamp of the data
C2350 XCAN address
1
Node address XCAN
(AIF interface X1)
1
{1}
63
C2351 XCAN baud
rate
0
Baud rate XCAN
(AIF interface X1)
0
500 kbps
1
250 kbit/sec
2
125 kbits/s
3
50 kbps
4
1000 kbit/s
C2352 XCAN mst
0
Establish XCAN master
operation.
(AIF interface X1)
0
Slave
1
Master