Function library
AIF1Out
254
EDBCSXS064 EN 4.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
[C6151]
Selection of the phase output
signals to the fieldbus module
1 AIF1Out−phi
1000
FIXED 0 (not assigned)
Source for output double word
AIF1Out-W2/W3
2 AIF2Out−phi
1000
FIXED 0 (not assigned)
Source for output double word
AIF2Out-W0/W1
3 AIF3Out−phi
1000
FIXED 0 (not assigned)
Source for output double word
AIF3Out-W0/W1
For possible signals see "selection list − phase
signals"
C6154 AIF1PdoMap
0
Assignment of the 8 byte user
data of the AIF1Out function
block to the fieldbus module
0
W2=Int W3=Int
Byte 1, byte 2 =
AIF1Out−DctrlStat
Byte 3, byte 4 = AIF1Out−W1
Byte 5, byte 6 = AIF1Out−W2
Byte 7, byte 8 = AIF1Out−W3
1
W2 / W3=Dint
Byte 1, byte 2 =
AIF1Out−DctrlStat
Byte 3, byte 4 = AIF1Out−W1
Byte 5, byte 6 = AIF1Out−W2/W3
Byte 7, byte 8 = AIF1Out−W2/W3
2
W2=Int W3=bit
Byte 1, byte 2 =
AIF1Out−DctrlStat
Byte 3, byte 4 = AIF1Out−W1
Byte 5, byte 6 = AIF1Out−W2
Byte 7, byte 8 =
AIF1Out−Bit0...Bit15
3
W2=Bit W3=Int
Byte 1, byte 2 =
AIF1Out−DctrlStat
Byte 3, byte 4 = AIF1Out−W1
Byte 5, byte 6 =
AIF1Out−Bit0...Bit15
Byte 7, byte 8 = AIF1Out−W3
4
W1=Bit W23=I
Byte 1, byte 2 =
AIF1Out−DctrlStat
Byte 3, byte 4 =
AIF1Out−Bit0...Bit15
Byte 5, byte 6 = AIF1Out−W2
Byte 7, byte 8 = AIF1Out−W3
5
W1=Bit W23=Di
Byte 1, byte 2 =
AIF1Out−DctrlStat
Byte 3, byte 4 =
AIF1Out−Bit0...Bit15
Byte 5, byte 6 = AIF1Out−W2/W3
Byte 7, byte 8 = AIF1Out−W2/W3