Function library
FCODE (free codes)
310
EDBCSXS064 EN 4.0
Codes
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C0017 FCODE (Qmin)
50
Free code for using speed signals
(Speed signal FCODE_nC17_a)
−16000
{1 rpm}
16000
C0037 Set−value rpm
0
Setpoint selection in rpm
(FCODE_nC37_a)
−16000
{1 rpm}
16000
C0108
Gain for relative analog signals
(AOUT)
1 FCODE(gain)
100.0
−199.99
{0.01 %}
199.99 FCODE_nC108_1_a
2 FCODE(gain)
100.0
FCODE_nC108_2_a
C0109
Offset for relative analog signals
(AOUT)
1 FCODE(offset)
0.0
−199.99
{0.01 %}
199.99 FCODE_nC109_1_a
2 FCODE(offset)
0.0
FCODE_nC109_2_a
C0135 Control word
0
System control word DCTRL
0
{1}
65535 Controller evaluates information
as 16 bits (binary−coded)
Bit 0
Not assigned
Bit 1
Not assigned
Bit 2
Not assigned
Bit 3
Quick stop (QSP)
Bit 4
Not assigned
Bit 5
Not assigned
Bit 6
Not assigned
Bit 7
Not assigned
Bit 8
Operation inhibit (DISABLE)
Bit 9
Controller inhibit (CINH)
Bit 10
TRIP−SET
Bit 11
TRIP−RESET
Bit 12
Not assigned
Bit 13
Not assigned
Bit 14
Not assigned
Bit 15
Not assigned
C0141 FCODE(setval)
0.0
Main setpoint (FCODE_C141_a)
−199.99
{0.01 %}
199.99
C0250 FCODE 1 Bit
0
Freely selectable digital signal
(1 bit)
0
1
C0470
Freely configurable code for
digital signals
Hexadecimal value is bit−coded.
1 FCODE 8bit
0
00
{hex}
FF C0470/1 = C0471, bit 0 ... 7
2 FCODE 8bit
0
C0470/2 = C0471, bit 8 ... 15
3 FCODE 8bit
0
C0470/3 = C0471, bit 16 ... 23
4 FCODE 8bit
0
C0470/4 = C0471, bit 24 ... 31