Table 3. DSA diagnostic messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 7, “Parts listing, ThinkServer RD220 Type 3729, 3779, 3797, and 3798,” on page 231 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message
number
Component
Test
State
Description
Action
215-803-xxx
Optical Drive
v
Verify
Media
Installed
v
Read/
Write
Test
v
Self-Test
Messages
and actions
apply to all
three tests.
Failed
The disc might
be in use by
the system.
1. Wait for the system activity to stop.
2. Run the test again
3. Turn off and restart the system.
4. Run the test again.
5. Replace the CD or DVD drive (see
“Removing a CD-RW/DVD drive” on
page 213 and “Installing a
CD-RW/DVD drive” on page 214).
6. If the failure remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/
docview.wss?uid=psg1SERVCALL.
215-901-xxx
Optical Drive
v
Verify
Media
Installed
v
Read/
Write
Test
v
Self-Test
Messages
and actions
apply to all
three tests.
Aborted
Drive media is
not detected.
1. Insert a CD or DVD into the drive or
try a new media, and wait for 15
seconds.
2. Run the test again.
3. Check the drive cabling at both ends
for loose or broken connections or
damage to the cable. Replace the
cable if it is damaged.
4. Run the test again.
5. For additional troubleshooting
information, go to
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
6. Run the test again.
7. Replace the CD or DVD drive (see
“Removing a CD-RW/DVD drive” on
page 213 and “Installing a
CD-RW/DVD drive” on page 214).
8. If the failure remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/
docview.wss?uid=psg1SERVCALL.
Chapter 5. Diagnostics
117
Содержание THINKSERVER 3729
Страница 1: ...Hardware Maintenance Manual ThinkServer RD220 Types 3797 3798 3779 and 3729 ...
Страница 2: ......
Страница 3: ...ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 8: ...vi ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 156: ...148 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 238: ...230 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 262: ...Japanese recycling statements 254 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 264: ...256 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 265: ......
Страница 266: ...Part Number 40M2493 Printed in USA 1P P N 40M2493 ...