Table 3. DSA diagnostic messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 7, “Parts listing, ThinkServer RD220 Type 3729, 3779, 3797, and 3798,” on page 231 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message
number
Component
Test
State
Description
Action
202-901-xxx
Memory
Memory
Stress Test
Failed
Test failure.
1. Run the standard memory test to
validate all memory.
2. Make sure that the DSA code is at the
latest level. For the latest level of DSA
code, go to http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
DSA.
3. Turn off the system and disconnect it
from power.
4. Reseat the DIMMs (see “Removing a
memory module (DIMM)” on page 186
and “Installing a DIMM” on page 192).
5. Reconnect the system to power and
turn on the system.
6. Run the test again.
114
ThinkServer RD220 Types 3729, 3779, 3797, and 3798: Hardware Maintenance Manual
Содержание THINKSERVER 3729
Страница 1: ...Hardware Maintenance Manual ThinkServer RD220 Types 3797 3798 3779 and 3729 ...
Страница 2: ......
Страница 3: ...ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 8: ...vi ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 156: ...148 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 238: ...230 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 262: ...Japanese recycling statements 254 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 264: ...256 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 265: ......
Страница 266: ...Part Number 40M2493 Printed in USA 1P P N 40M2493 ...