1
Virtual media key connector
2
Virtual media key (front)
3
Mounting bracket (rear)
4
Mounting tab
To install a virtual media key, complete the following steps:
1. Read the safety information that begins on page 3.
2. Turn off the server and peripheral devices and disconnect all power cords and
external cables (see “Turning off the server” on page 53).
3. Remove the cover (see “Removing the cover” on page 159).
4. Align the mounting bracket on the rear of the virtual media key with the
mounting tab and slide it down the tab onto the virtual medial key connector on
the system board. Press the virtual media key down into the connector until it is
firmly seated on the system board.
If you have other optional devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 227.
Removing a memory module (DIMM)
To remove a DIMM, complete the following steps.
1. Read the safety information that begins on page 3.
2. Turn off the server and peripheral devices and disconnect all power cords and
external cables.
3. Slide the server out of the rack.
4. Remove the cover (see “Removing the cover” on page 159).
5. If riser-card assembly 1 contains one or more adapters, remove it (see
“Removing a PCI riser-card assembly” on page 167).
186
ThinkServer RD220 Types 3729, 3779, 3797, and 3798: Hardware Maintenance Manual
Содержание THINKSERVER 3729
Страница 1: ...Hardware Maintenance Manual ThinkServer RD220 Types 3797 3798 3779 and 3729 ...
Страница 2: ......
Страница 3: ...ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 8: ...vi ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 156: ...148 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 238: ...230 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 262: ...Japanese recycling statements 254 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 264: ...256 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Страница 265: ......
Страница 266: ...Part Number 40M2493 Printed in USA 1P P N 40M2493 ...