Procedure
Step 1. Touch the static-protective package that contains the new OCP 3.0 Ethernet adapter to any
unpainted surface on the outside of the server. Then, take the new OCP 3.0 Ethernet adapter out of
the package and place it on a static-protective surface.
Step 2. Remove the OCP 3.0 Ethernet adapter filler if there is.
Step 3. Install the OCP 3.0 Ethernet adapter.
Notes:
• Ensure that the Ethernet adapter is fully seated and the thumbscrew is securely tightened.
Otherwise, the OCP 3.0 Ethernet adapter will not get full connection and may not function.
• If there is an OCP 3.0 Ethernet adapter installed, when the system is powered off but still
plugged in to AC power, system fans will continue to spin at a much lower speed. This is the
system design to provide proper cooling for the OCP 3.0 Ethernet adapter.
Figure 114. OCP 3.0 Ethernet adapter installation
a. Push the OCP 3.0 Ethernet adapter as shown to insert it into the connector on the system
board.
b. Tighten the thumbscrew to secure the card.
Step 4. Attach the OCP label to the rear of the server.
.
Hardware replacement procedures
263
Содержание 7D2V
Страница 1: ...ThinkSystem SR665 Maintenance Manual Machine Types 7D2V and 7D2W ...
Страница 6: ...iv ThinkSystem SR665 Maintenance Manual ...
Страница 10: ...viii ThinkSystem SR665 Maintenance Manual ...
Страница 66: ...56 ThinkSystem SR665 Maintenance Manual ...
Страница 82: ...Figure 25 Cable routing for configuration 4 72 ThinkSystem SR665 Maintenance Manual ...
Страница 111: ...BP 3 NVMe 2 3 PCIe 3 BP 3 NVMe 4 5 PCIe 7 BP3 NVMe 6 7 PCIe 8 Chapter 3 Internal cable routing 101 ...
Страница 123: ...Figure 40 Cable routing for configuration 1 Chapter 3 Internal cable routing 113 ...
Страница 126: ...Figure 42 Cable routing for configuration 2 116 ThinkSystem SR665 Maintenance Manual ...
Страница 131: ...Figure 45 Cable routing for configuration 6 Chapter 3 Internal cable routing 121 ...
Страница 133: ...Chapter 3 Internal cable routing 123 ...
Страница 148: ...138 ThinkSystem SR665 Maintenance Manual ...
Страница 167: ...Chapter 4 Hardware replacement procedures 157 ...
Страница 216: ...Step 2 Connect the cables to the backplanes See 7mm drives on page 64 206 ThinkSystem SR665 Maintenance Manual ...
Страница 237: ...Chapter 4 Hardware replacement procedures 227 ...
Страница 299: ...Chapter 4 Hardware replacement procedures 289 ...
Страница 300: ...On the 2 5 inch middle drive cage 290 ThinkSystem SR665 Maintenance Manual ...
Страница 339: ...Chapter 4 Hardware replacement procedures 329 ...
Страница 364: ...354 ThinkSystem SR665 Maintenance Manual ...
Страница 408: ...398 ThinkSystem SR665 Maintenance Manual ...
Страница 431: ...5 Reseat the failing device 6 Replace the failing device Chapter 5 Problem determination 421 ...
Страница 444: ...434 ThinkSystem SR665 Maintenance Manual ...
Страница 445: ... Copyright Lenovo 2019 435 ...
Страница 448: ...438 ThinkSystem SR665 Maintenance Manual ...
Страница 449: ... Copyright Lenovo 2019 439 ...
Страница 452: ...442 ThinkSystem SR665 Maintenance Manual ...
Страница 464: ...454 ThinkSystem SR665 Maintenance Manual ...
Страница 465: ......
Страница 466: ......