Table 1. Server specifications (continued)
Specification
Description
Internal drives
Front:
• Up to twenty-four 2.5-inch hot-swap SAS/SATA/NVMe drives
• Up to twelve 3.5-inch hot-swap SAS/SATA/NVMe drives
Middle/Inside:
• Up to eight 2.5-inch hot-swap SAS/SATA/NVMe drives
• Up to four 3.5-inch hot-swap SAS/SATAdrives
• Up to two internal SATA/NVMe M.2 drives
(On Air baffle or middle drive bays)
Rear:
• Up to eight 2.5-inch hot-swap SAS/SATA drives
• Up to four 3.5-inch hot-swap SAS/SATA drives
• Up to two 7mm hot-swap SATA/NVMe drives
For technical rules for drives, see “Drive bay configurations and requirements” on page 139.
Expansion slots
• Your server supports up to eight PCIe slots in the rear:
– PCIe x16/x8/x8, full-height
– PCIe x16/x16/E*, full-height
– PCIe E*/x16/x16, full-height
– PCIe x16/x16, full-height
– PCIe x8/x8, full-height
– PCIe x16, full-height
Note:
“E” is short for “empty”. It means the slot in the three-slot riser card is unavailable.
• Your server supports up to one slot for OCP 3.0 Ethernet adapter
For technical rules for PCIe slots, see “Rear view” on page 33 and “Technical rules for PCIe
slots” on page 144.
Graphics processing
unit (GPU)
Your server supports the following GPUs:
• Low-profile, half-length, double-wide: NVIDIA
®
Tesla
®
V100, V100S
• Full-height, full-length, single-wide: NVIDIA Quadro
®
P620, NVIDIA Tesla T4
For technical rules for GPU, see “Technical rules for GPU” on page 147.
Input/Output (I/O)
features
• Front :
– One VGA connector (optional)
– One USB 3.1 Gen 1 connector and one USB 2.0 connector with XClarity Controller
management
– One external diagnostics connector
– One diagnostics panel or LCD diagnostics panel (optional)
• Rear:
– One VGA connector
– Three USB 3.1 Gen 1 connectors
– One XClarity Controller network connector
– Two or four Ethernet connectors on the OCP 3.0 Ethernet adapter (optional)
4
ThinkSystem SR665 Maintenance Manual
Содержание 7D2V
Страница 1: ...ThinkSystem SR665 Maintenance Manual Machine Types 7D2V and 7D2W ...
Страница 6: ...iv ThinkSystem SR665 Maintenance Manual ...
Страница 10: ...viii ThinkSystem SR665 Maintenance Manual ...
Страница 66: ...56 ThinkSystem SR665 Maintenance Manual ...
Страница 82: ...Figure 25 Cable routing for configuration 4 72 ThinkSystem SR665 Maintenance Manual ...
Страница 111: ...BP 3 NVMe 2 3 PCIe 3 BP 3 NVMe 4 5 PCIe 7 BP3 NVMe 6 7 PCIe 8 Chapter 3 Internal cable routing 101 ...
Страница 123: ...Figure 40 Cable routing for configuration 1 Chapter 3 Internal cable routing 113 ...
Страница 126: ...Figure 42 Cable routing for configuration 2 116 ThinkSystem SR665 Maintenance Manual ...
Страница 131: ...Figure 45 Cable routing for configuration 6 Chapter 3 Internal cable routing 121 ...
Страница 133: ...Chapter 3 Internal cable routing 123 ...
Страница 148: ...138 ThinkSystem SR665 Maintenance Manual ...
Страница 167: ...Chapter 4 Hardware replacement procedures 157 ...
Страница 216: ...Step 2 Connect the cables to the backplanes See 7mm drives on page 64 206 ThinkSystem SR665 Maintenance Manual ...
Страница 237: ...Chapter 4 Hardware replacement procedures 227 ...
Страница 299: ...Chapter 4 Hardware replacement procedures 289 ...
Страница 300: ...On the 2 5 inch middle drive cage 290 ThinkSystem SR665 Maintenance Manual ...
Страница 339: ...Chapter 4 Hardware replacement procedures 329 ...
Страница 364: ...354 ThinkSystem SR665 Maintenance Manual ...
Страница 408: ...398 ThinkSystem SR665 Maintenance Manual ...
Страница 431: ...5 Reseat the failing device 6 Replace the failing device Chapter 5 Problem determination 421 ...
Страница 444: ...434 ThinkSystem SR665 Maintenance Manual ...
Страница 445: ... Copyright Lenovo 2019 435 ...
Страница 448: ...438 ThinkSystem SR665 Maintenance Manual ...
Страница 449: ... Copyright Lenovo 2019 439 ...
Страница 452: ...442 ThinkSystem SR665 Maintenance Manual ...
Страница 464: ...454 ThinkSystem SR665 Maintenance Manual ...
Страница 465: ......
Страница 466: ......