5. Remove the hard disk drive from the computer to gain access to the system board. See “Replacing the
primary hard disk drive” on page 81.
6. Carefully take note of the location of all cable connections on the system board and disconnect all cables.
See “Locating parts on the system board” on page 66.
7. Remove the screws that secure the system board to the chassis.
8. Lift the system board out of the chassis.
9. Remove the memory modules from the failing system board and install them in the same location on the
new system board. See “Replacing a memory module” on page 69.
10. Remove the heat sink and fan assembly from the failing system board. See “Replacing the heat sink and
fan assembly” on page 71.
11. Remove the retention module from the rear of the failing system board and install it in the same position
on the new system board.
12. Remove the microprocessor from the failing system board and install it on the new system board. See
“Replacing the microprocessor” on page 73.
13. Reinstall the heat sink and fan assembly. See “Replacing the heat sink and fan assembly” on page
71. And connect the heat sink and fan assembly cable to the system board. See “Replacing the heat
sink and fan assembly” on page 71.
14. Install the new system board into the chassis and align the screw holes with those in the chassis. Insert
and tighten the screws that secure the system board.
15. Reinstall the hard disk drive back into position. See “Replacing the primary hard disk drive” on page 81.
16. Reconnect the power and signal cables to the hard disk drive.
17. Reconnect all remaining cables to the system board. See “Locating parts on the system board” on
page 66.
18. Go to “Completing the parts replacement” on page 94.
The failing system board must be returned with a microprocessor socket cover to protect the pins during
shipping and handling.
To install the microprocessor socket cover, do the following:
1. Release the lever securing the microprocessor retainer and open the retainer to access the
microprocessor.
2. Grasp the microprocessor on the sides and lift it straight up and out of the socket. Do not touch the
contacts on the microprocessor socket.
3. Note the orientation of the socket cover. Align the notches
1
of the microprocessor socket cover with
the alignment keys
2
of the microprocessor socket.
4. Install one side of the socket cover into the microprocessor socket as shown.
76
ThinkCentre Hardware Maintenance Manual
Содержание 3699
Страница 2: ......
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 46: ...40 ThinkCentre Hardware Maintenance Manual ...
Страница 68: ...62 ThinkCentre Hardware Maintenance Manual ...
Страница 102: ...96 ThinkCentre Hardware Maintenance Manual ...
Страница 572: ...566 ThinkCentre Hardware Maintenance Manual ...
Страница 576: ...570 ThinkCentre Hardware Maintenance Manual ...
Страница 577: ......
Страница 578: ...Part Number Printed in USA 1P P N ...