Diagnostic Error Code
FRU/Action
018-197-XXX
PCI Card test warning
1. Make sure the component that is called out is
connected and/or enabled. See “” on page .
2. Re-run the test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
018-198-XXX
PCI Card test aborted
1. If a component is called out, make sure it is connected
and/or enabled. See “” on page .
2. Flash the system and re-test. See “Updating (flashing)
BIOS from a disc” on page 564.
3. Go to “Undetermined problems” on page 60.
018-199-XXX
PCI Card test failed, cause unknown
1. Go to “Undetermined problems” on page 60.
2. Flash the system and re-test. See “Updating (flashing)
BIOS from a disc” on page 564.
3. Replace component under function test.
018-250-XXX
PCI Card Services error
1. PCI card
2. Riser card, if installed
3. System board
020-000-XXX
PCI Interface Test Passed
No action
020-0XX-XXX
PCI Interface error
1. PCI card
2. Riser card, if installed
3. System board
020-195-XXX
PCI Test aborted by user
Information only Restart the test, if necessary.
020-196-XXX
PCI test halt, error threshold exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
020-197-XXX
PCI test warning
1. Make sure the component that is called out is
connected and/or enabled. See “” on page .
2. Re-run the test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
020-198-XXX
PCI test aborted
1. If a component is called out, make sure it is connected
and/or enabled. See “” on page .
2. Flash the system and re-test. See “Updating (flashing)
BIOS from a disc” on page 564.
3. Go to “Undetermined problems” on page 60.
020-199-XXX
PCI test failed, cause unknown
1. Go to “Undetermined problems” on page 60.
2. Flash the system and re-test. See “Updating (flashing)
BIOS from a disc” on page 564.
3. Replace component under function test.
020-262-XXX
PCI system error
1. PCI card
2. Riser card, if installed
3. System board
025-000-XXX
IDE interface Test Passed
No action
Chapter 7
.
Symptom-to-FRU index
49
Содержание 3699
Страница 2: ......
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 46: ...40 ThinkCentre Hardware Maintenance Manual ...
Страница 68: ...62 ThinkCentre Hardware Maintenance Manual ...
Страница 102: ...96 ThinkCentre Hardware Maintenance Manual ...
Страница 572: ...566 ThinkCentre Hardware Maintenance Manual ...
Страница 576: ...570 ThinkCentre Hardware Maintenance Manual ...
Страница 577: ......
Страница 578: ...Part Number Printed in USA 1P P N ...