Diagnostic Error Code
FRU/Action
001-032-XXX
System Device Controller failure
System board
001-034-XXX
System Device Buffer Allocation failure
1. Reboot the system
2. Flash the system. See “Updating (flashing) BIOS from
a disc” on page 564.
3. Run memory test
4. System board
001-035-XXX
System Device Reset condition detected
System board
001-036-XXX
System Register error
System board
001-038-XXX
System Extension failure
1. Adapter card
2. System board
001-039-XXX
System DMI data structure error
1. Flash the system. See “Updating (flashing) BIOS from
a disc” on page 564.
2. System board
001-040-XXX
System IRQ failure
1. Turn off/on the system and re-test.
2. System board
001-041-XXX
System DMA failure
1. Turn off/on the system and re-test.
2. System board
001-195-XXX
System Test aborted by user
Information only Restart the test, if necessary.
001-196-XXX
System test halt, error threshold exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
001-197-XXX
System test warning
1. Make sure the component that is called out is
connected and/or enabled. See “” on page .
2. Re-run test
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
001-198-XXX
System test aborted
1. If a component is called out, make sure it is connected
and/or enabled. See “” on page .
2. Flash the system and retest. See “Updating (flashing)
BIOS from a disc” on page 564.
3. Go to “Undetermined problems” on page 60.
001-199-XXX
System test failed, cause unknown
1. Go to “Undetermined problems” on page 60.
2. Flash the system and re-test.
3. Replace component under function test.
001-250-XXX
System ECC error
System board
001-254-XXX 001-255-XXX 001-256-XXX 001-257-XXX
System DMA error
System board
001-260-XXX 001-264-XXX
System IRQ error
System board
001-268-XXX
System IRQ1 failure
1. Device on IRQ1
2. System board
001-269-XXX
System IRQ2 failure
1. Device on IRQ2
2. System board
44
ThinkCentre Hardware Maintenance Manual
Содержание 3699
Страница 2: ......
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 46: ...40 ThinkCentre Hardware Maintenance Manual ...
Страница 68: ...62 ThinkCentre Hardware Maintenance Manual ...
Страница 102: ...96 ThinkCentre Hardware Maintenance Manual ...
Страница 572: ...566 ThinkCentre Hardware Maintenance Manual ...
Страница 576: ...570 ThinkCentre Hardware Maintenance Manual ...
Страница 577: ......
Страница 578: ...Part Number Printed in USA 1P P N ...