NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS  •  MERIT PLUS

®

 DIRECT VENT GAS FIREPLACES (MPD33/35/40/45)  •  INSTALLATION INSTRUCTIONS

Use only approved vent components (see 

Approved Vent Components

 on 

Page 2).

These fireplaces must be vented directly 

to the outside.

The vent system may not service multiple 

appliances, and must never be connected to 

a flue serving a separate solid fuel burning 

appliance. The vent pipe is tested to be run 

inside an enclosed wall (such as a chase). There 

is no requirement for inspection openings in the 

enclosing wall at any of the joints in the vent pipe. 

Step 3. PREPARING APPLIANCE VENT 

COLLAR  (

MPd35/-40/-45 models with 

combined top/rear vent)

Each of the unit’s two vent collars are sealed 

with a cover plate and a seal plate and gasket. 

The cover, and seal plate and gasket must be 

removed from the vent collar being used. Refer 

to 

Figure 15

 for top vent usage and 

Figure 16

 

for rear, and the following steps to prepare the 

appropriate collar for use.

From the vent collar being used, remove the four 

screws securing the vent seal plate and gasket. 

Remove and discard the seal plate and gasket.

When the top vent collar is being used

, from 

inside the firebox, loosen the two screws in the 

keyhole slots of the cover plate and remove the 

remaining two cover plate securing screws. 

Remove and discard the cover plate. 

Reinstall 

and securely tighten all four screws.

When the rear vent collar is being used

, from 

inside the firebox, remove the two screws 

securing the lintel to the rear wall of the firebox, 

then remove the lintel. Remove the four cover 

plate securing screws. Remove and discard 

the cover plate. 

Reinstall and securely tighten all four cover 

plate screws. Re-secure the lintel to the rear 

wall of the firebox. 

Figure 15 - Top vent seal and cover plate 

removal  -  MPD35/40/45  series  models 

(combined top and rear vent units)

Step 4. INSTALLING VENT SYSTEM

 

These instructions should be used as a 

guideline and do not supersede local codes 

in any way. Install venting according to local 

codes, these instructions, the current National 

Fuel Gas Code (ANSI-Z223.1) in the USA or 

the current standards of CAN/CGA-B149.1 

in Canada. 
Ensure clearances are in accordance with 

local installation codes and the requirements 

of the gas supplier.

dégagement conforme aux codes d'installa-

tion locaux et aux exigences du foumisseunde 

gaz.

Select Venting System - Horizontal or Vertical

With the appliance secured in framing, determine 

vent routing and identify the exterior termination 

location. The following sections describe 

vertical (roof) and horizontal (exterior wall) 

vent applications. Refer to the section relating 

to your installation.

 A list of approved venting 

components are shown on 

Pages 36 and 37.

U-SHAPED VENT

RESTRICTOR

APPLIANCE REAR

VENT OUTLET

A vent restrictor may be needed when

horzontally terminating the vent system from

the rear of the appliance (when using the

appliance rear vent), install vent restrictor in

the rear vent of the fireplace outlet on

MPD35/40/45 series models, in any

installation that has a vertical vent run in

excess of three feet (0.914 meters).

INNER FIREPLACE

COLLAR

If needed, install the restrictor orientated as

shown, either from inside or outside the unit,

in the inner fireplace collar.

Figure 16 - Rear vent seal and cover plate 

removal  -  MPD35/40/45  series  models 

(combined top and rear vent units)

Figure 18 -Vent restrictor installation - 
Rear vent

KNOCKOUT

GASKET

FIREBOX TOP

CABINET TOP

VENT

COVER PLATE

TOP VENT

TOP VENT SEAL AND COVER PLATE REMOVAL

WHEN USING THE TOP VENT

COVER PLATE

SECURING SCREWS

CROSS SECTION

(INSIDE UNIT)

(OUTSIDE UNIT)

KNOCKOUT

CAP AND

GASKET

CROSS SECTION

REAR VENT

COVER PLATE

SECURING SCREWS

CABINET BACK

(INSIDE UNIT)

(OUTSIDE UNIT)

REAR VENT SEAL AND COVER PLATE REMOVAL

WHEN USING THE REAR VENT

Figure 17 - Vent restrictor installation - 
Top vent

A vent restrictor may be needed when vertically 

terminating the vent system above the roof 

(when using the appliance top vent),install vent 

restrictor in the top vent of the fireplace outlet 

on MPd35/40/45 and MPdT33 series models.
If needed, install the restrictor orientated as 

shown, either from inside or outside the unit, 

in the inner fireplace collar.

U-Shaped Vent 
Restrictor

Inner Fireplace 
Collar

Appliance Top 

Vent Outlet

Installation of Vent Restrictor

A vent restrictor may be needed with this 

appliance, install vent restrictor (provided) 

in the appliance top flue outlet as shown in 

Figure 17

 

(MPDT33, MPD35, MPD40 and 

MPD45) or rear flue outlet as shown in

 

Figure 

18

 

(MPD35, MPD40 and MPD45). It is held in 

place by friction, only.

NOTE: The vent restrictor is included in the 

firebox.

       WARNING 

Failure to reinstall and securely 

tighten cover plate screws could 

result in leakage of flue products 

into the living space. Vent cover 

plate and vent seal cap must 

remain securely installed on 

unused vent collar. Failure to 

do so could result in leakage of 

flue products into living space.

Содержание MPD35CNE

Страница 1: ...fire or explosion may result causing property damage personal injury or death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLAS...

Страница 2: ...cal Installation Sequence 9 Detailed Installation Steps 9 Step 1 Framing 9 Fireplace and Framing Specifications 10 Step 2 Routing Gas Line 11 Step 3 Preparing Appliance Vent Collar 12 Step 4 Installin...

Страница 3: ...is appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning WARNING Failure to position the parts in accordance with these diagrams or failure to use only par...

Страница 4: ...55 0 052 19L52 MPD40 38 0 102 99K76 0 062 21L01 MPD45 37 0 104 24M10 52 0 0635 37G00 Table 4 Standard size installed at factory Part Cat Number REQUIREMENTS FOR THE COMMONWEALTHOFMASSACHUSETTS These f...

Страница 5: ...the appliance Cold Climate Insulation For cold climate installations seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room It is especially imp...

Страница 6: ...ents Above Flat Or Sloped Roofs Ref NFPA 54 ANSI Z223 1 Roof Pitch H ft H m Flat 6 12 1 0 0 3 6 12 7 12 1 25 0 38 7 12 8 12 1 5 0 46 8 12 9 12 2 0 0 61 9 12 10 12 2 5 0 76 10 12 11 12 3 25 0 99 11 12...

Страница 7: ...er 5 12 7 cm 5 12 7 cm G Clearance to inside corner 2 5 08cm minimum SV4 5HT 2 6 15 2cm minimum SV4 5HTSS 2 5 08cm minimum SV4 5HT 2 6 15 2cm minimum SV4 5HTSS H Clearancetoeachinsideofcenterlineexten...

Страница 8: ...ve to conform to standard hearth extension installation requirements Shelf Height To provide for the lowest possible shelf surface use the alternate rear vent outlet the venting attached to the top ve...

Страница 9: ...the framing and secure with nailing brackets IMPORTANT Bend up the appropriate header spacing standoffs for the drywall finish material thickness to be used see Figure 11 Bend up the outer pair for 1...

Страница 10: ...lectrical Inlet Knockout requiring a Field Provided Junction Box either side E B D C Front View 3 76 A Header Spacing Top Standoffs Vertical Venting through the Ceiling Frame ceiling opening Use a plu...

Страница 11: ...aming 6 1 2 152 mm Pipe Coupling Recommended NOTE Rear Vent Applications in Corner Installations The horizontal vent length from a to b must not exceed 28 inches 711 mm MPDT33 and MPDR33 Models Dimens...

Страница 12: ...ct Venting System Horizontal or Vertical Withtheappliancesecuredinframing determine ventroutingandidentifytheexteriortermination location The following sections describe vertical roof and horizontal e...

Страница 13: ...4 1 1 0 0 5 0 6 3 8 1 5 2 5 1 0 1 0 5 0 6 6 8 1 5 5 1 0 0 0 0 4 4 5 0 9 1 5 7 8 5 1 1 0 0 0 4 5 5 6 9 1 5 7 3 6 1 0 1 0 0 4 5 5 5 0 2 5 2 1 7 1 0 1 1 5 0 7 7 0 2 5 2 7 1 0 0 0 6 0 6 5 1 1 2 5 2 6 7 1...

Страница 14: ...e radial alignment until the four locking dimples are aligned with the inlet of the four inclined channels on the collar refer to Figure 21 Push the vent component againstthecollaruntilitfullyengages...

Страница 15: ...llar section to align with the required direction of the next vent run element Twist elbow sections in a clockwise direction only so as to avoid the possiblity of unlocking anyofthepreviouslyconnected...

Страница 16: ...ou are allowed 2 feet of H horizontal run up to a maximum horizontal run of 8 feet Example If 8 feet of H horizontal vent run is needed then 4 feet minimum V vertical vent will be required TABLE A H M...

Страница 17: ...6 096 4 1 219 H H1 20 feet 6 096 m Max V V1 H H1 40 ft 12 192 m Max meters meters Example If 20 feet of H horizontal vent run is needed then 4 feet minimum of V vertical vent will be required This tab...

Страница 18: ...al both the inner and outer pipe elements with the same procedure Sealant and securing screws are not required NOTE An elbow may also be attached to the appliance collar Attach in the same manner as y...

Страница 19: ...4 32 mm as shown in Figure 34 SVHRK Snorkel Cap The snorkel cap is designed to be fitted into a basement window box The SVHRK cap is for use with flex vent The vertical distance between the inlet and...

Страница 20: ...owingwallthicknessrange when using SV4 5HT 2 termination kit HORIZONTAL Vent Figures Tables NOTE Secure Vent components rigid vent pipe and terminal are shown in the figures Secure Flex components fle...

Страница 21: ...of H horizontal vent run is needed then 4 feet minimum of V vertical vent will be required This table shows a 1 V to 5 H ratio For every 1 foot of V vertical you are allowed 5 feet of H horizontal run...

Страница 22: ...al rise except where an elbow is the only vertical component in the system See Figure 36 V Minimum feet feet 5 1 524 Elbow Only 5 1 524 1 0 305 10 3 048 2 0 610 15 4 572 3 0 914 20 6 096 4 1 219 meter...

Страница 23: ...No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slide the inner flex pipe over the adaptor collar Ensure the flexible vent pip...

Страница 24: ...t of 2 conductor wire supplied with the unit NOTE The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed l...

Страница 25: ...eplace The millivolt control valve has a 3 8 10mm NPT thread inlet port The electronic control valve has a 1 2 13 mm NPT thread inlet port and is fitted with a 1 2 x 3 8 13 mm x 10 mm NPT fitting Secu...

Страница 26: ...onovertime A Light the appliance refer to the lighting instructionslabelinthecontrolcompartment or in the Care and Operation Instructions manual B Brush all joints and connections with the gas leak te...

Страница 27: ...pli ances to Figure 54 for MPD35 Series appli ancesandtoFigure55forMPD40andMPD45 Series appliances WARNING DO NOT attempt to install the logs until the appliance instal lationhasbeencompleted the gas...

Страница 28: ...firebox with the log s notches directly over the brackets Position the right log log no 3 by inserting the pin from the rear log into the hole on its upper end Place the left log and then the smaller...

Страница 29: ...the order shown Position the rear log on the brackets at the rear of the firebox with the log s notches directly over the brackets Position the right log log no 3 by inserting the pin from the rear l...

Страница 30: ...ividual logs as shown below Logs should be placed in the order shown Position the center log on the burner first then place the glowing embers as shown in Figure 52 Place the rear log both the right a...

Страница 31: ...t appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation Figure 56 Removing the Glass Enclosure Panel see Figure 56 Remove the to...

Страница 32: ...ireplace rod located in the lower control area Position the air shutter to the factory setting as shown in the table in Figure 60 2 Light appliance follow lighting procedure on lighting label in contr...

Страница 33: ...bustible material may touch top of appliance Combustible materials NOT allowed below this point on face of appliance Header Spacing Top Standoff Top of Appliance Top of Door Frame Hood must be install...

Страница 34: ...er la poussi re et les traces de graisse ou d huile Collez l tiquette sur la surface de la plaque de l interrupteur mural qui contr le le foyer Figure A ou du thermostat mural Figure B Choisissez la l...

Страница 35: ...6 SV4 5HF 10 Firestop Spacer Hori zontal rigid 3 1 1 spac ing 10 Pack H2247 SV4 5VF 10 Firestop Spacer Verti cal rigid 1 1 1 spac ing 10 Pack 96K92 SV4 5SP Support Plate Installation Accessories Liste...

Страница 36: ...T48SS Small Square Termination for flex with 48 1219 mm of compressed flex vent Ref Instr 750204M 94L09 SF HTSS Horizontal Small Square Termination for flex without flex vent Ref Instr 750204M INSTALL...

Страница 37: ...pin located at the door s left side to the right until it disengages from the left corner post hole Pull the control compartment door diagonally to the left away from the fireplace Step 3 Remove the...

Страница 38: ...crews previously removed Step 12 Reinstall the baffle with the two baffle securing screws Step 13 Reassemble the remaining compo nents by reversing the procedures outlined in the Steps 1 5 Step 14 Att...

Отзывы: