background image

34

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS  •  MERIT PLUS

®

 DIRECT VENT GAS FIREPLACES (MPD33/35/40/45)  •  INSTALLATION INSTRUCTIONS

ATTACHING SAFETY IN OPERATION WARNINGS 

It is required that the safety instruction labels 

furnished with the fireplace be affixed to the op-

eration and control point of the fireplace.  A safety 

instruction label must be affixed to the wall switch 

plate where the fireplace is turned on and off 

(See 

Figure A

)

 or wall thermostat 

(See 

Figure B

)

 and if 

used on the remote control handheld transmitter 

(

Figure C

)

.  To properly complete the installation of 

this fireplace, locate the multi-lingual adhesive labels 

provided with the Care and Operation Instructions 

and proceed as follows:
1.  Locate the wall switch or wall thermostat that 

controls the fireplace (verify the switch operates 

the fireplace by turning it on and off).  Clean the 

wall switch plate or wall thermostat thoroughly 

to remove any dust and oils. Affix the label to 

the surface of the plate of the wall switch that 

controls the fireplace 

(

Figure A

)

 or the wall 

thermostat 

(

Figure B

)

.   Choose the language 

primarily spoken in the home. If unknown, affix 

the English language label.

2.  If a remote control is used to control the fireplace, 

locate the transmitter and clean it thoroughly 

to remove any dust and oils.  Affix the label to 

the surface of handheld transmitter 

(

Figure C

)

.   

Choose the language primarily spoken in the 

home. If unknown, affix the English language 

label.

3.  If you are unable to locate the labels, please call 

Lennox Hearth Products or your nearest Lennox 

Hearth Products dealer to receive additional 

safety instruction labels free of charge.

Cat. No. H8024 Replacement Label Kit 

LENNOX HEARTH PROdUCTS

1-800-655-2008

NOTE: English is red text on clear label. French 

and Spanish are white text on black label.

STEP 13. INSTALLER INSTRUCTIONS -

 

ATTACHING SAFETY IN OPERATION WARNINGS

It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a 

critical step in informing consumers of safe operation of this appliance.

APPOSITION dES MISES EN GARdE RELATIVES 

à LA SéCURITé d’UTILISATION 

Il est impératif que les étiquettes de sécurité fournies 

avec le foyer soient collées à côté des dispositifs 

de contrôle du foyer.  Une étiquette de sécurité doit 

être collée sur la plaque de l’interrupteur contrôlant 

l’allumage du foyer 

(voir 

Figure A

)

 ou sur le thermostat 

mural 

(voir 

Figure B

)

 et, le cas échéant, sur le boîtier de 

la télécommande 

(

Figure C

)

. Pour achever l’instal lation 

correcte de ce foyer, procédez comme suit avec les 

étiquettes adhésives en langues étrangères fournies 

avec les instructions d’utilisation et d’entretien :
1. Repérez l’interrupteur ou le thermostat mural 

qui contrôle le foyer (vérifiez que l’interrupteur 

contrôle le fonctionnement du foyer en le faisant 

basculer de Marche à Arrêt, et vice-versa). Nettoyez 

soigneusement la plaque murale de l’interrupteur 

ou le thermostat mural pour éliminer la poussière 

et les traces de graisse ou d’huile. Collez l’étiquette 

sur la surface de la plaque de l’interrupteur mural 

qui contrôle le foyer 

(

Figure A

)

 ou du thermostat 

mural 

(

Figure B

)

. Choisissez la langue qui est 

principalement parlée dans la résidence du 

propriétaire. En cas de doute, collez l’étiquette en 

anglais.

2.  Si une télécommande est utilisée pour contrôler le 

foyer, nettoyez la soigneusement pour éliminer la 

poussière et les traces de graisse ou d’huile.  Collez 

l’étiquette sur le boîtier de la télé commande 

(

Figure 

C

)

. Choisissez la langue qui est principalement parlée 

dans la résidence du proprié taire. En cas de doute, 

collez l’étiquette en anglais.

3.  Si vous ne trouvez pas les étiquettes, veuillez 

appeler Lennox Hearth Products ou votre distribu-

teur Lennox Hearth Products local pour recevoir 

gratuitement des étiquettes supplémentaires.

Étiquettes de remplacement, n° cat. H8024 

LENNOX HEARTH PROdUCTS

1-800-655-2008

Remarque : Le texte anglais est rouge sur un support 

transparent. Le texte français et espagnol est blanc 

sur un support noir.

COLOCACIóN dE AdVERTENCIAS dE SEGURIdAd 

EN OPERACIóN 

Se requiere que las etiquetas de instrucciones de 

seguridad incluidas con la chimenea se coloquen en 

el punto de operación y control de la misma. Se debe 

colocar una etiqueta de instrucciones de seguridad 

en la placa del interruptor de pared desde el cual 

se enciende y se apaga la chimenea 

(ver la 

Figura 

A

)

 o en el termostato de pared 

(ver la 

Figura B

)

 y 

en el transmisor de control remoto 

(

Figura C

)

 si se 

usa. Para completar correctamente la instalación de 

esta chimenea, encuentre las etiquetas adhesivas 

multilingües incluidas con las instrucciones de cuidado 

y operación y haga lo siguiente:
1.  Identifique el interruptor o el termostato de pared 

que controla la chimenea (verifique que el interruptor 

opera la chimenea encendiéndola y apagándola). 

Limpie bien la placa del interruptor o el termostato de 

pared para quitar el polvo y aceite. Pegue la etiqueta 

en la superficie de la placa del interruptor que controla 

la chimenea 

(

Figura A

)

 o en el termostato de pared 

(

Figura B

)

.

 

Seleccione el idioma que más se habla 

en la casa. Si no sabe cuál es, use la etiqueta en 

inglés.

2. Si se usa un control remoto para controlar la 

chimenea, encuentre el transmisor y límpielo bien 

para quitar el polvo y aceite. Pegue la etiqueta en 

la superficie del transmisor 

(

Figura C

)

.

 

Seleccione 

el idioma que más se habla en la casa. Si no sabe 

cuál es, use la etiqueta en inglés.

3.   Si no puede encontrar las etiquetas, sírvase llamar a 

Lennox Hearth Products o al distribuidor de Lennox 

Hearth Products más cercano para recibir etiquetas 

de instrucciones de seguridad adicionales gratuitas. 

Juego de etiquetas de repuesto - Nº de cat. H8024 

LENNOX HEARTH PROdUCTS

1-800-655-2008

Nota: La etiqueta en inglés es transparente con texto 

rojo. Las etiquetas en francés y español son negras 

con texto blanco.

Figure A 

Figure B

Figure C

SAFETY LABEL dIAGRAMS

dIAGRAMAS dE ETIQUETAS dE 

SEGURIdAd

dIAGRAMMES dES éTIQUETTES 

dE SéCURITé

Illustrations are for example only. 

Your accessories may be different.

Les illustrations sont par exemple 

uniquement. Vos accessoires 

peuvent être différents.

Las ilustraciones son sólo ejemplos. 

Tu accesorios pueden ser diferentes.

Содержание MPD35CNE

Страница 1: ...fire or explosion may result causing property damage personal injury or death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLAS...

Страница 2: ...cal Installation Sequence 9 Detailed Installation Steps 9 Step 1 Framing 9 Fireplace and Framing Specifications 10 Step 2 Routing Gas Line 11 Step 3 Preparing Appliance Vent Collar 12 Step 4 Installin...

Страница 3: ...is appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning WARNING Failure to position the parts in accordance with these diagrams or failure to use only par...

Страница 4: ...55 0 052 19L52 MPD40 38 0 102 99K76 0 062 21L01 MPD45 37 0 104 24M10 52 0 0635 37G00 Table 4 Standard size installed at factory Part Cat Number REQUIREMENTS FOR THE COMMONWEALTHOFMASSACHUSETTS These f...

Страница 5: ...the appliance Cold Climate Insulation For cold climate installations seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room It is especially imp...

Страница 6: ...ents Above Flat Or Sloped Roofs Ref NFPA 54 ANSI Z223 1 Roof Pitch H ft H m Flat 6 12 1 0 0 3 6 12 7 12 1 25 0 38 7 12 8 12 1 5 0 46 8 12 9 12 2 0 0 61 9 12 10 12 2 5 0 76 10 12 11 12 3 25 0 99 11 12...

Страница 7: ...er 5 12 7 cm 5 12 7 cm G Clearance to inside corner 2 5 08cm minimum SV4 5HT 2 6 15 2cm minimum SV4 5HTSS 2 5 08cm minimum SV4 5HT 2 6 15 2cm minimum SV4 5HTSS H Clearancetoeachinsideofcenterlineexten...

Страница 8: ...ve to conform to standard hearth extension installation requirements Shelf Height To provide for the lowest possible shelf surface use the alternate rear vent outlet the venting attached to the top ve...

Страница 9: ...the framing and secure with nailing brackets IMPORTANT Bend up the appropriate header spacing standoffs for the drywall finish material thickness to be used see Figure 11 Bend up the outer pair for 1...

Страница 10: ...lectrical Inlet Knockout requiring a Field Provided Junction Box either side E B D C Front View 3 76 A Header Spacing Top Standoffs Vertical Venting through the Ceiling Frame ceiling opening Use a plu...

Страница 11: ...aming 6 1 2 152 mm Pipe Coupling Recommended NOTE Rear Vent Applications in Corner Installations The horizontal vent length from a to b must not exceed 28 inches 711 mm MPDT33 and MPDR33 Models Dimens...

Страница 12: ...ct Venting System Horizontal or Vertical Withtheappliancesecuredinframing determine ventroutingandidentifytheexteriortermination location The following sections describe vertical roof and horizontal e...

Страница 13: ...4 1 1 0 0 5 0 6 3 8 1 5 2 5 1 0 1 0 5 0 6 6 8 1 5 5 1 0 0 0 0 4 4 5 0 9 1 5 7 8 5 1 1 0 0 0 4 5 5 6 9 1 5 7 3 6 1 0 1 0 0 4 5 5 5 0 2 5 2 1 7 1 0 1 1 5 0 7 7 0 2 5 2 7 1 0 0 0 6 0 6 5 1 1 2 5 2 6 7 1...

Страница 14: ...e radial alignment until the four locking dimples are aligned with the inlet of the four inclined channels on the collar refer to Figure 21 Push the vent component againstthecollaruntilitfullyengages...

Страница 15: ...llar section to align with the required direction of the next vent run element Twist elbow sections in a clockwise direction only so as to avoid the possiblity of unlocking anyofthepreviouslyconnected...

Страница 16: ...ou are allowed 2 feet of H horizontal run up to a maximum horizontal run of 8 feet Example If 8 feet of H horizontal vent run is needed then 4 feet minimum V vertical vent will be required TABLE A H M...

Страница 17: ...6 096 4 1 219 H H1 20 feet 6 096 m Max V V1 H H1 40 ft 12 192 m Max meters meters Example If 20 feet of H horizontal vent run is needed then 4 feet minimum of V vertical vent will be required This tab...

Страница 18: ...al both the inner and outer pipe elements with the same procedure Sealant and securing screws are not required NOTE An elbow may also be attached to the appliance collar Attach in the same manner as y...

Страница 19: ...4 32 mm as shown in Figure 34 SVHRK Snorkel Cap The snorkel cap is designed to be fitted into a basement window box The SVHRK cap is for use with flex vent The vertical distance between the inlet and...

Страница 20: ...owingwallthicknessrange when using SV4 5HT 2 termination kit HORIZONTAL Vent Figures Tables NOTE Secure Vent components rigid vent pipe and terminal are shown in the figures Secure Flex components fle...

Страница 21: ...of H horizontal vent run is needed then 4 feet minimum of V vertical vent will be required This table shows a 1 V to 5 H ratio For every 1 foot of V vertical you are allowed 5 feet of H horizontal run...

Страница 22: ...al rise except where an elbow is the only vertical component in the system See Figure 36 V Minimum feet feet 5 1 524 Elbow Only 5 1 524 1 0 305 10 3 048 2 0 610 15 4 572 3 0 914 20 6 096 4 1 219 meter...

Страница 23: ...No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slide the inner flex pipe over the adaptor collar Ensure the flexible vent pip...

Страница 24: ...t of 2 conductor wire supplied with the unit NOTE The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed l...

Страница 25: ...eplace The millivolt control valve has a 3 8 10mm NPT thread inlet port The electronic control valve has a 1 2 13 mm NPT thread inlet port and is fitted with a 1 2 x 3 8 13 mm x 10 mm NPT fitting Secu...

Страница 26: ...onovertime A Light the appliance refer to the lighting instructionslabelinthecontrolcompartment or in the Care and Operation Instructions manual B Brush all joints and connections with the gas leak te...

Страница 27: ...pli ances to Figure 54 for MPD35 Series appli ancesandtoFigure55forMPD40andMPD45 Series appliances WARNING DO NOT attempt to install the logs until the appliance instal lationhasbeencompleted the gas...

Страница 28: ...firebox with the log s notches directly over the brackets Position the right log log no 3 by inserting the pin from the rear log into the hole on its upper end Place the left log and then the smaller...

Страница 29: ...the order shown Position the rear log on the brackets at the rear of the firebox with the log s notches directly over the brackets Position the right log log no 3 by inserting the pin from the rear l...

Страница 30: ...ividual logs as shown below Logs should be placed in the order shown Position the center log on the burner first then place the glowing embers as shown in Figure 52 Place the rear log both the right a...

Страница 31: ...t appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation Figure 56 Removing the Glass Enclosure Panel see Figure 56 Remove the to...

Страница 32: ...ireplace rod located in the lower control area Position the air shutter to the factory setting as shown in the table in Figure 60 2 Light appliance follow lighting procedure on lighting label in contr...

Страница 33: ...bustible material may touch top of appliance Combustible materials NOT allowed below this point on face of appliance Header Spacing Top Standoff Top of Appliance Top of Door Frame Hood must be install...

Страница 34: ...er la poussi re et les traces de graisse ou d huile Collez l tiquette sur la surface de la plaque de l interrupteur mural qui contr le le foyer Figure A ou du thermostat mural Figure B Choisissez la l...

Страница 35: ...6 SV4 5HF 10 Firestop Spacer Hori zontal rigid 3 1 1 spac ing 10 Pack H2247 SV4 5VF 10 Firestop Spacer Verti cal rigid 1 1 1 spac ing 10 Pack 96K92 SV4 5SP Support Plate Installation Accessories Liste...

Страница 36: ...T48SS Small Square Termination for flex with 48 1219 mm of compressed flex vent Ref Instr 750204M 94L09 SF HTSS Horizontal Small Square Termination for flex without flex vent Ref Instr 750204M INSTALL...

Страница 37: ...pin located at the door s left side to the right until it disengages from the left corner post hole Pull the control compartment door diagonally to the left away from the fireplace Step 3 Remove the...

Страница 38: ...crews previously removed Step 12 Reinstall the baffle with the two baffle securing screws Step 13 Reassemble the remaining compo nents by reversing the procedures outlined in the Steps 1 5 Step 14 Att...

Отзывы: