background image

3

LENNOX HEARTH PRODUCTS  •  MONTEBELLO

® 

 DLX DIRECT VENT GAS FIREPLACES (MDLX40/45)  •  INSTALLATION INSTRUCTIONS

       WARNING 

Young children should be care-

fully supervised when they are 

in the same room as the appli-

ance. Toddlers, young children 

and others may be susceptible 

to accidental contact burns. A 

physical barrier is recommended 

if there are at risk individuals in 

the house. To restrict access to 

a fireplace or stove, install an 

adjustable safety gate to keep 

toddlers, young children and 

other at risk individuals out of 

the room and away from hot 

surfaces.

       AVERTISSEMENT 

Les jeunes enfants devraient être 

surveillés étroitement lorsqu’ils 

se trouvent dans la même pièce 

que l’appareil. Les tout petits, 

les jeunes enfants ou les adultes 

peuvent subir des brûlures s’ils 

viennent en contact avec la sur-

face chaude. Il est recommandé 

d’installer une barrière physique 

si des personnes à risques habi-

tent la maison. Pour empêcher 

l’accès à un foyer ou à un poêle, 

installez une barrière de sécu-

rité; cette mesure empêchera les 

tout petits, les jeunes enfants et 

toute autre personne à risque 

d’avoir accès à la pièce et aux 

surfaces chaudes.

GENERAL INFORMATION

Children and adults should be alerted to the 

hazards of high surface temperature and 

should stay away to avoid burns or clothing 

ignition. 

Les enfants et les adultes devraient être 

infor-més des dangers que posent les 

températures de surface élevées et se 

tenir à distance afin d’éviter des brûlures 

ou que leurs vêtements ne s’enflamment.

DO NOT ATTEMPT TO ALTER OR MODIFY  

THE CONSTRUCTION OF THE APPLIANCE OR 

ITS COMPONENTS. ANY MODIFICATION OR 

ALTERATION MAY VOID THE WARRANTY,  

CERTIFICATION AND LISTINGS OF THIS UNIT.

Installation and repair should be done by 

a qualified service person. The appliance 

should be inspected before use and at least 

annually by a professional service person. 

More frequent cleaning may be required due 

to excessive lint from carpeting, bedding ma-

terial, etcetera. It is imperative that control 

compartments, burners and circulating air 

passageways of the appliance be kept clean.

L’installation et la réparation devrait 

être confiées à un technicien qualifié. 

L’appareil devrait faire l’objet d’une in-

spection par un technicien professionnel 

avant d’être utilisé et au moins une fois 

l’an par la suite. Des nettoyages plus 

fréquents peuvent être nécessaires si les 

tapis, la literie, et cetera produisent une 

quantité importante de pous-sière. Il est 

essentiel que les compartiments abritant 

les commandes, les brûleurs et les con-

duits de circulation d’air de l’appareil 

soient tenus propres.

Do not use this appliance if any part has 

been under water. Immediately call a 

qualified service technician to inspect the 

appliance and to replace any parts of the 

control system and any gas control which 

have been under water.

Ne pas se servir de cet appareil s'il a été 

plongé dans l'eau, complètement ou en 

partie. Appeler un technicien qualifié 

pour inspecter l'appareil et remplacer 

toute partie du système de contrôle et 

toute commande qui ont été plongés 

dans l'eau.

Only trim kit(s) supplied by the manufacturer 

shall be used in the installation of this ap-

pliance.

Seules les trousses de garniture fournies 

par le fabricant doivent être utilisées pour 

l’installation de cet appareil.

Provide adequate clearances around air open-

ings and adequate accessibility clearance for 

service and proper operation. Never obstruct 

the front openings of the appliance.

These appliances are designed to operate on 

natural or propane gas only. The use of other 

fuels or combination of fuels will degrade 

the performance of this system and may be 

dangerous.

These appliances must not be connected to a 

chimney or flue serving a separate solid fuel 

burning appliance.

       WARNING 

Improper installation, adjust-

ment, alteration, service or 

maintenance can cause injury 

or property damage. Refer to 

this manual. For assistance or 

additional information consult 

a qualified installer, service 

agency or the gas supplier.

       WARNING 

Failure to comply with these 

installation instructions will result 

in an improperly installed and 

operating appliance, voiding its 

warranty. Any change to this appli-

ance and/or its operating controls 

is dangerous.

       WARNING 

Clothing or other flammable 

material should not be placed 

on or near the appliance.

       AVERTISSEMENT 

On ne devrait pas placer de 

vêtements ni d’autres matières 

inflammables sur l’appareil ni à 

proximité.

       WARNING 

Any safety screen or guard 

removed for servicing the appli-

ance must be replaced prior to 

operating the appliance.

       AVERTISSEMENT 

Tout écran ou protecteur retiré 

pour permettre l’entretien de 

l’appareil doit être remis en 

place avant de mettre l’appareil 

en marche.

       WARNING 

Improper installation or use of 

this appliance can cause serious 

injury or death from fire, burns, 

explosion or carbon monoxide 

poisoning.

Содержание Montebello MDLX40IN

Страница 1: ...NE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y TOUCHER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS...

Страница 2: ...eps 9 Typical Installation Sequence 9 Step 1 Framing 9 Fireplace and Framing Specifications 10 Step 2 Routing Gas Line 11 Proper Sizing of Gas Line 11 Step 3 Install the Vent System 12 Vertical Termin...

Страница 3: ...euvent tre n cessaires si les tapis la literie et cetera produisent une quantit importante de pous si re Il est essentiel que les compartiments abritant les commandes les br leurs et les con duits de...

Страница 4: ...aximum Natural Gas 5 5 WC 1 37 kPa 10 5 WC 2 61 kPa Propane 11 0 WC 2 74 kPa 13 0 WC 3 23 kPa Table 2 Manifold Gas Supply Pressure Fuel Low High Natural Gas 1 6 WC 4 kPa 3 5 WC 87 kPa Propane 6 3 WC 1...

Страница 5: ...ted manufactured home and must be installed in accordance with the manu facturer s instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the United States o...

Страница 6: ...Opening H H MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT TERMINATION HEIGHTS FOR VENTS ABOVE FLAT OR SLOPED ROOFS Horizontal Overhang Vertical Wall Vent Termination Storm Collar Concen...

Страница 7: ...mbustion air inlet to any other appliance 6 15 2cm forappliances 10 000BTU hr 3kW 12 30 cm for appliances 10 000 BTU hr 3kW and 100 000 BTU hr 30kW 36 91 cm for appliances 100 000 BTU hr 30kW 6 15 2 c...

Страница 8: ...nce requirements include any projections such as shelves window sills mantels etc above the appliance NOTE We recommend the use of high temperature paint rated 175 F or higher on the underside of the...

Страница 9: ...r wrapper Combustible framing may be in direct contact with the nailing flanges and may be located closer than 1 2 from screw heads and the firebox wrapper in areas adjacent to the nailing flanges Fra...

Страница 10: ...1039 Notes Diagrams illustrations and photo graphs are not to scale consult installation instructions Product designs materials dimensions specifications colors and prices are subject to change or dis...

Страница 11: ...m an improper installation such as this is not covered under the limited warranty Right Side Front Corner Of Fireplace Framing 6 1 4 159 mm 19 5 8 498 mm Step 2 Routing Gas Line Route a 1 2 13 mm gas...

Страница 12: ...places must be vented directly to the outside The vent system may not service multiple appliances and must never be connected to a flue serving a separate solid fuel burning ap pliance The vent pipe i...

Страница 13: ...2 5 0 1 5 7 8 0 0 1 0 0 0 1 5 1 5 2 1 1 1 0 0 0 2 5 9 1 5 2 6 1 2 1 0 0 0 3 1 2 5 7 1 0 2 0 0 0 2 5 2 2 5 7 8 1 0 0 1 0 0 1 5 5 2 5 2 1 2 1 2 0 0 0 3 5 1 3 5 2 6 2 0 3 0 0 0 3 5 4 3 5 7 8 2 0 0 0 1 0...

Страница 14: ...osition is indicated by the alignment of the arrow and dimple as shown in Figure 17 D Install firestop spacer at ceiling When using Secure Vent use SV8BF firestop spacer at ceiling joists If there is...

Страница 15: ...r axis of their initial collar section to align with the required direc tion of the next vent run element Twist elbow sections in a clockwise direction only so as to avoid the possibility of unlocking...

Страница 16: ...own in the figures It is very important that the horizontal inclined run be maintained in a straight no dips slightly elevated plane The recommended incline is approximately 1 4 perfoot 20mmpermeter h...

Страница 17: ...installation of the straight vent sections in horizontal inclined run as described in Step E on Page 14 Install support straps every 3 feet 1914 mm along horizontal inclinedventrunsusingconventional...

Страница 18: ...nded that the Firestop Spacer SV4 5HF be installed on the exterior side of the wall J Assemble vent run to exterior wall If not previously measured locate the center of the vent at the exterior wall P...

Страница 19: ...5 1 37 10 5 3 2 5 5 1 68 12 5 3 8 6 5 1 98 14 5 4 4 7 5 2 3 16 5 5 0 8 5 2 6 18 5 5 6 9 5 2 9 20 6 0 10 3 0 V H 40 feet 12 4 m Max H 20 ft 6 2 m Max HORIZONTAL Vent Figures Tables NOTES Secure Vent c...

Страница 20: ...F Wall Firestop Spacer SV8HF Ceiling Firestop Spacer SV8BF Table D H H1 Maximum V Minimum feet meter feet meter 3 5 1 07 2 5 0 762 6 5 1 98 3 5 1 07 8 5 2 6 4 5 1 37 10 5 3 2 5 5 1 68 12 5 3 8 6 5 1 9...

Страница 21: ...22 1 Cana dian Electrical Code Verify proper operation after servicing S assurer que l appareil fonctionne ad quatement une fois l entretien termin A wiring diagram is provided here for reference purp...

Страница 22: ...REMOTE position Figure 34 7 On the receiver front cover insert the end of a paper clip or other similar object not provided into the hole marked PRG The receiver will beep three times to indicate it i...

Страница 23: ...n accordance with building codes by a quali fied installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation mustbeperformedbyalicensed plumber or...

Страница 24: ...ianceasafe reliableandattractive flame pattern Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Lo...

Страница 25: ...er Engage Logs 3 4 With The Grate Pins And Align Groves At The Bottom Of The Logs Over The Grate 4 3 Engage Log 6 With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Align Hole...

Страница 26: ...e closed position then operate the appliance for a few more minutes to ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the c...

Страница 27: ...ngy If this is problematic or persists as the appliance is continually operated adjust the air shutter closedasdescribedinthepreviousparagraphs Operatetheapplianceforaperiodoftimeasthe effect diminish...

Страница 28: ...e appliance The gray shaded area must be non combustible or Dura Rock Header 2x4 s Spacers Top of Door Frame Fireplace right side Combustible Finished Wall Materials 1 Installations with horizontal te...

Страница 29: ...z lasoigneuse ment pour liminer la poussi re et les traces degraisseoud huile Collezl tiquettesurlebo tier de la t l commande Figure B Choisissez la langue qui est principalement parl e dans la r side...

Страница 30: ...8 SV8FA 1 12 to 7 12 Adjust able Flashing H2259 SV8FB 7 12 to 12 12 Adjustable Flashing H3237 SV8SC6 Storm Collars 6 pack H2260 SV8HF Firestop Spacer Horizontal 3 1 1 spacing H2261 SV8BF Firestop Spac...

Страница 31: ...nce with the manufacturer s instructions and all applicable codes andrequirementsoftheauthorityhavingjurisdiction Iftheinformationin these instruction is not followed exactly a fire explosion or produ...

Страница 32: ...ps Step 14 Attach the conversion label provided in the conversion kit to the rating plate on the appliance Step 15 Apply gas to the system and relight appliance With the main burner ON test the new pr...

Страница 33: ...33 LENNOX HEARTH PRODUCTS MONTEBELLO DLX DIRECT VENT GAS FIREPLACES MDLX40 45 INSTALLATION INSTRUCTIONS NOTES...

Страница 34: ...t notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX...

Отзывы: