INTRODUCTION 

The 

Montebello

®

 DLX

 direct-vent, sealed-

combustion gas fireplaces operate on natural 

or propane gas. These appliances feature a 

remotely controlled electronic intermittent pilot 

ignition system (manual adjustment of the gas 

valve settings is not possible). 

The Montebello DLX is a decorative fireplace 

and may not be installed and operated as the 

primary heat source in a dwelling.

Electrical power (120 VAC line voltage) is rec-

ommended to operate the fireplace; however, 

four (4) "AA" batteries can be used for full-time 

operation or as a backup in case of a power 

outage.

Approved Vent Components

These fireplaces are designed, tested, and 

listed for operation and installation with 

Secure 

Vent

®

 direct vent system components (8" inner, 

11" outer) manufactured by Security Chimneys 

International.

These approved vent system components 

are labeled for identification. 

USE ONLY AP-

PROVED VENT COMPONENTS. Do NOT use 

any other manufacturer’s vent components 

with these appliances.

Codes and Standards

These appliances comply with National Safety 

Standards and are tested and listed by Intertek 

(Report No. 100513650) to Z21.50 (in Canada, 

CSA-2.22),  and  CAN/CGA-2.17-M91  in  both 

USA and Canada, as vented gas fireplaces.

These appliances are listed by Intertek for 

installation in bedrooms and mobile homes.

Installation must conform to local codes. In 

the absence of local codes, installation must 

comply with the current National Fuel Gas 

Code,  ANSI  Z223.1  (in  Canada,  the  current 

CAN/CGA-B149.1 installation code). 

The appliance, when installed, must be electri-

cally grounded in accordance with local codes 

or, in the absence of local codes, with the 

National Electrical Code, ANSI/NFPA 70 (latest 

edition) or the Canadian Electrical Code, CSA 

C22.1 (latest edition).

TABLE OF CONTENTS 

Packaging   . . . . . . . . . . . . . . . . . . . . . . . . . 2
Introduction  . . . . . . . . . . . . . . . . . . . . . . . . 2
General Information  . . . . . . . . . . . . . . . . . . 3
Massachusetts Requirements  . . . . . . . . . .  4
Cold Climate Insulation   . . . . . . . . . . . . . . . 5
Manufactured Home Requirements  . . . . . . 5
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Vent Termination Clearances  . . . . . . . . . . . 6
Minimum Clearances to Combustibles  . . . . . 8
Detailed Installation Steps  . . . . . . . . . . . . .  9
Typical Installation Sequence   . . . . . . . . . .  9
Step 1.  Framing  . . . . . . . . . . . . . . . . . . . .  9
Fireplace and Framing Specifications . . . . . . 10
Step 2.  Routing Gas Line  . . . . . . . . . . . . . 11
Proper Sizing of Gas Line . . . . . . . . . . . . . . 11
Step 3.  Install the Vent System   . . . . . . . . 12
Vertical Termination Systems . . . . . . . . . . . 13
Vent Section Length Chart  . . . . . . . . . . . . . 13
Vertical Vent Tables and Figures . . . . . . . . . 16
Horizontal Termination System   . . . . . . . . . 17
Horizontal Vent Tables and Figures   . . . . . . 19
Step 4.  Field Wiring  . . . . . . . . . . . . . . . . . 21
Step 5.  Removing Glass Door
    Frame Assembly   . . . . . . . . . . . . . . . . . . 23
Step 6.  Connecting Gas Line   . . . . . . . . . . 23
Step 7.  Checking Appliance 
    Operation  . . . . . . . . . . . . . . . . . . . . . . . . 23
Step 8.  Installing Logs and Panels  . . . . . . 24
Step 9.  Installing Glass Door  . . . . . . . . . . 26
Step 10.  Burner Adjustments  . . . . . . . . . . . 26
Finishing Requirements  . . . . . . . . . . . . . . . 28
Step 11. Attaching Safety-in-
    Operation Warnings  . . . . . . . . . . . . . . . . 29
Installation Accessories  . . . . . . . . . . . . . . . 30
Gas Conversion Kits . . . . . . . . . . . . . . . . . . 31

Please read and understand these 

instructions before beginning your 

installation.

PACKAGING

The assembled fireplace is packaged with the 

following:
• 

Literature Kit

 (plastic bag shipped inside 

firebox),  containing  Care and Operation 

Instructions,  Installation Instructions (this 

manual),  Safety-in-Operation  Warning  La-

bels, and Warranty. 

•  One (1) bag 

Glowing Embers

•  One (1) bag 

Platinum Embers

•  One (1) bag 

Volcanic Stone

• 

Pull Screen Kit

• 

Remote Control and Wall Receiver Switch 

Kit

• 

Door Modesty Shield

• 

Log Grate 

 NOTE

: For use with fireplace as shipped from fac-

tory only. Not for use with Contemporary Burner/

Floor Kit.

REQUIRED ACCESSORIES

The following accessories are required:
•  One of the following 

Firebox Liner Kits

:

a. 

Ceramic Firebox Liner Kit - Buff Rustic

b. 

Ceramic Firebox Liner Kit - Red Rustic

c. 

Porcelain Firebox Liner Kit - Black 

d. 

Ceramic Firebox Liner Kit - Red Her-

ringbone

e. 

Ceramic Firebox Liner Kit - Buff Her-

ringbone

 NOTE: 

Porcelain kits include side and back panels. 

Optional for use with log sets. Required when 

using the contemporary burner/floor kit.

•  One of the following 

Floor Options

:

a. 

Oak Log Set 

(For use with fireplace as 

shipped from factory only. Not for use with 

contemporary burner/floor kit.)

b. 

Contemporary Burner/Floor Kit

  Contemporary Burner/Floor Kit requires 

one of the following 

Media Kits

:

i.  Crushed Glass - Reflective Black

ii.  Crushed Glass - Platinum

iii.  Crushed Glass - Reflective Blue

iv.  Crushed Glass - Goldfinger

v.  Crushed Glass - Copper

 NOTE

:

 

The Contemporary Burner/Floor Kit instal-

lation and operation instructions are provided 

with the kit, and are not detailed in this manual.

 

Содержание Montebello MDLX40IN

Страница 1: ...NE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y TOUCHER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS...

Страница 2: ...eps 9 Typical Installation Sequence 9 Step 1 Framing 9 Fireplace and Framing Specifications 10 Step 2 Routing Gas Line 11 Proper Sizing of Gas Line 11 Step 3 Install the Vent System 12 Vertical Termin...

Страница 3: ...euvent tre n cessaires si les tapis la literie et cetera produisent une quantit importante de pous si re Il est essentiel que les compartiments abritant les commandes les br leurs et les con duits de...

Страница 4: ...aximum Natural Gas 5 5 WC 1 37 kPa 10 5 WC 2 61 kPa Propane 11 0 WC 2 74 kPa 13 0 WC 3 23 kPa Table 2 Manifold Gas Supply Pressure Fuel Low High Natural Gas 1 6 WC 4 kPa 3 5 WC 87 kPa Propane 6 3 WC 1...

Страница 5: ...ted manufactured home and must be installed in accordance with the manu facturer s instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the United States o...

Страница 6: ...Opening H H MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT TERMINATION HEIGHTS FOR VENTS ABOVE FLAT OR SLOPED ROOFS Horizontal Overhang Vertical Wall Vent Termination Storm Collar Concen...

Страница 7: ...mbustion air inlet to any other appliance 6 15 2cm forappliances 10 000BTU hr 3kW 12 30 cm for appliances 10 000 BTU hr 3kW and 100 000 BTU hr 30kW 36 91 cm for appliances 100 000 BTU hr 30kW 6 15 2 c...

Страница 8: ...nce requirements include any projections such as shelves window sills mantels etc above the appliance NOTE We recommend the use of high temperature paint rated 175 F or higher on the underside of the...

Страница 9: ...r wrapper Combustible framing may be in direct contact with the nailing flanges and may be located closer than 1 2 from screw heads and the firebox wrapper in areas adjacent to the nailing flanges Fra...

Страница 10: ...1039 Notes Diagrams illustrations and photo graphs are not to scale consult installation instructions Product designs materials dimensions specifications colors and prices are subject to change or dis...

Страница 11: ...m an improper installation such as this is not covered under the limited warranty Right Side Front Corner Of Fireplace Framing 6 1 4 159 mm 19 5 8 498 mm Step 2 Routing Gas Line Route a 1 2 13 mm gas...

Страница 12: ...places must be vented directly to the outside The vent system may not service multiple appliances and must never be connected to a flue serving a separate solid fuel burning ap pliance The vent pipe i...

Страница 13: ...2 5 0 1 5 7 8 0 0 1 0 0 0 1 5 1 5 2 1 1 1 0 0 0 2 5 9 1 5 2 6 1 2 1 0 0 0 3 1 2 5 7 1 0 2 0 0 0 2 5 2 2 5 7 8 1 0 0 1 0 0 1 5 5 2 5 2 1 2 1 2 0 0 0 3 5 1 3 5 2 6 2 0 3 0 0 0 3 5 4 3 5 7 8 2 0 0 0 1 0...

Страница 14: ...osition is indicated by the alignment of the arrow and dimple as shown in Figure 17 D Install firestop spacer at ceiling When using Secure Vent use SV8BF firestop spacer at ceiling joists If there is...

Страница 15: ...r axis of their initial collar section to align with the required direc tion of the next vent run element Twist elbow sections in a clockwise direction only so as to avoid the possibility of unlocking...

Страница 16: ...own in the figures It is very important that the horizontal inclined run be maintained in a straight no dips slightly elevated plane The recommended incline is approximately 1 4 perfoot 20mmpermeter h...

Страница 17: ...installation of the straight vent sections in horizontal inclined run as described in Step E on Page 14 Install support straps every 3 feet 1914 mm along horizontal inclinedventrunsusingconventional...

Страница 18: ...nded that the Firestop Spacer SV4 5HF be installed on the exterior side of the wall J Assemble vent run to exterior wall If not previously measured locate the center of the vent at the exterior wall P...

Страница 19: ...5 1 37 10 5 3 2 5 5 1 68 12 5 3 8 6 5 1 98 14 5 4 4 7 5 2 3 16 5 5 0 8 5 2 6 18 5 5 6 9 5 2 9 20 6 0 10 3 0 V H 40 feet 12 4 m Max H 20 ft 6 2 m Max HORIZONTAL Vent Figures Tables NOTES Secure Vent c...

Страница 20: ...F Wall Firestop Spacer SV8HF Ceiling Firestop Spacer SV8BF Table D H H1 Maximum V Minimum feet meter feet meter 3 5 1 07 2 5 0 762 6 5 1 98 3 5 1 07 8 5 2 6 4 5 1 37 10 5 3 2 5 5 1 68 12 5 3 8 6 5 1 9...

Страница 21: ...22 1 Cana dian Electrical Code Verify proper operation after servicing S assurer que l appareil fonctionne ad quatement une fois l entretien termin A wiring diagram is provided here for reference purp...

Страница 22: ...REMOTE position Figure 34 7 On the receiver front cover insert the end of a paper clip or other similar object not provided into the hole marked PRG The receiver will beep three times to indicate it i...

Страница 23: ...n accordance with building codes by a quali fied installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation mustbeperformedbyalicensed plumber or...

Страница 24: ...ianceasafe reliableandattractive flame pattern Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Lo...

Страница 25: ...er Engage Logs 3 4 With The Grate Pins And Align Groves At The Bottom Of The Logs Over The Grate 4 3 Engage Log 6 With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Align Hole...

Страница 26: ...e closed position then operate the appliance for a few more minutes to ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the c...

Страница 27: ...ngy If this is problematic or persists as the appliance is continually operated adjust the air shutter closedasdescribedinthepreviousparagraphs Operatetheapplianceforaperiodoftimeasthe effect diminish...

Страница 28: ...e appliance The gray shaded area must be non combustible or Dura Rock Header 2x4 s Spacers Top of Door Frame Fireplace right side Combustible Finished Wall Materials 1 Installations with horizontal te...

Страница 29: ...z lasoigneuse ment pour liminer la poussi re et les traces degraisseoud huile Collezl tiquettesurlebo tier de la t l commande Figure B Choisissez la langue qui est principalement parl e dans la r side...

Страница 30: ...8 SV8FA 1 12 to 7 12 Adjust able Flashing H2259 SV8FB 7 12 to 12 12 Adjustable Flashing H3237 SV8SC6 Storm Collars 6 pack H2260 SV8HF Firestop Spacer Horizontal 3 1 1 spacing H2261 SV8BF Firestop Spac...

Страница 31: ...nce with the manufacturer s instructions and all applicable codes andrequirementsoftheauthorityhavingjurisdiction Iftheinformationin these instruction is not followed exactly a fire explosion or produ...

Страница 32: ...ps Step 14 Attach the conversion label provided in the conversion kit to the rating plate on the appliance Step 15 Apply gas to the system and relight appliance With the main burner ON test the new pr...

Страница 33: ...33 LENNOX HEARTH PRODUCTS MONTEBELLO DLX DIRECT VENT GAS FIREPLACES MDLX40 45 INSTALLATION INSTRUCTIONS NOTES...

Страница 34: ...t notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX...

Отзывы: