22

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS  •  MONTEBELLO

® 

 DLX DIRECT VENT GAS FIREPLACES (MDLX40/45)  •  INSTALLATION INSTRUCTIONS

Installing and initializing the Remote 

 Control  System

REQUIRED ITEMS (not provided):

• Standard Junction Box
• Paper Clip or similar object (for remote 

control system initialization)

Installing and Wiring the Receiver  

(Wall Switch)

The receiver for the Total Comfort Control™ 

Remote  Control System connects directly to 

the gas valve, stepper motor, and fan control 

module with an umbilical cord wiring harness. 
1.  Install a junction box (not provided) on 

the wall adjacent to the appliance, within 

reach of the remote system umbilical cord 

wiring harness. Position the 6-pin termi-

nal within the junction box in preparation 

for attachment to the remote receiver.

2.  When wall finish is complete, install the 

receiver in the previously installed junc-

tion box, and connect the 6-pin terminal 

to the 6-pin connector on the back of the 

receiver.

3.  Install the receiver cover plate, taking care 

to ensure the receiver switch is properly 

indexed with the switch cover when align-

ing the components for attachments.

Initializing the Remote Control System

After completing fireplace installation, initialize 

the remote control system before operating 

the fireplace.
4.  Insert the three (3) provided AAA batteries 

into the battery bay in the transmitter, tak-

ing care to correctly align polarity (+/ - ). 

5.  Insert the four (4) provided AA batteries 

into the receiver battery bay (behind the 

wall switch plate), taking care to correctly 

align polarity (+/ - ).

6.  On the receiver, place the three-position 

slider  switch  in  the  REMOTE  position 

(

Figure 34

). 

7.  On the receiver front cover, insert the end 

of a paper clip (or other similar object; not 

provided) into the hole marked “PRG.” 

 

The  receiver  will  “beep”  three  times  to 

indicate it is ready to synchronize with 

the transmitter.

8.  On the transmitter, press the ON button. 

The  receiver  will  “beep”  four  times  to 

indicate acceptance of the transmitter’s 

command (and set the receiver to the 

transmitter’s specific code). The system 

is now initialized.

       WARNING

Fire hazard. Can cause severe 

injury or death. The receiver 

causes ignition of the appliance. 

The appliance can turn on 

suddenly. Keep away from 

the appliance burner when 

operating the remote system or 

activating manual bypass of the 

remote system.

       

CAUTION

Property damage hazard. Exces-

sive heat can cause property 

damage. The appliance can stay 

lit for many hours. Turn off the 

appliance if it is not going to be 

attended for any length of time. 

Always place the transmitter 

where children can not reach it.

Figure 34 - Receiver (Wall Switch)

Remote

Off

On

PRG

Three-position slider switch 
in REMOTE position

Figure 35 - Transmitter (Remote Control)

Hot Fireplace Will Cause

Severe Burns

Never Allow Children to

 

Touch Glass or other Fire-

place Parts

WARNING

LCD Display

ON/OFF Key

ROOM 

TEMP.

Key

UP/DOWN 

Arrow Key

MODE Key

The remote control system provides remote 

operation of the following fireplace functions:

• Primary burner ON/OFF
• Flame height and heat output adjustment 

(six levels)

The receiver accepts commands via radio 

frequency from the transmitter and does not 

require line-of-sight operation. 

The slider switch on the receiver can be set to 

one of three positions: 

• ON (manual override)
• OFF (manual override)
• REMOTE (remote control)

See the fireplace Care and Operation Instruc-

tions for detailed instructions on using the 

remote control system to operate the fireplace.

Содержание Montebello MDLX40IN

Страница 1: ...NE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y TOUCHER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS...

Страница 2: ...eps 9 Typical Installation Sequence 9 Step 1 Framing 9 Fireplace and Framing Specifications 10 Step 2 Routing Gas Line 11 Proper Sizing of Gas Line 11 Step 3 Install the Vent System 12 Vertical Termin...

Страница 3: ...euvent tre n cessaires si les tapis la literie et cetera produisent une quantit importante de pous si re Il est essentiel que les compartiments abritant les commandes les br leurs et les con duits de...

Страница 4: ...aximum Natural Gas 5 5 WC 1 37 kPa 10 5 WC 2 61 kPa Propane 11 0 WC 2 74 kPa 13 0 WC 3 23 kPa Table 2 Manifold Gas Supply Pressure Fuel Low High Natural Gas 1 6 WC 4 kPa 3 5 WC 87 kPa Propane 6 3 WC 1...

Страница 5: ...ted manufactured home and must be installed in accordance with the manu facturer s instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the United States o...

Страница 6: ...Opening H H MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT TERMINATION HEIGHTS FOR VENTS ABOVE FLAT OR SLOPED ROOFS Horizontal Overhang Vertical Wall Vent Termination Storm Collar Concen...

Страница 7: ...mbustion air inlet to any other appliance 6 15 2cm forappliances 10 000BTU hr 3kW 12 30 cm for appliances 10 000 BTU hr 3kW and 100 000 BTU hr 30kW 36 91 cm for appliances 100 000 BTU hr 30kW 6 15 2 c...

Страница 8: ...nce requirements include any projections such as shelves window sills mantels etc above the appliance NOTE We recommend the use of high temperature paint rated 175 F or higher on the underside of the...

Страница 9: ...r wrapper Combustible framing may be in direct contact with the nailing flanges and may be located closer than 1 2 from screw heads and the firebox wrapper in areas adjacent to the nailing flanges Fra...

Страница 10: ...1039 Notes Diagrams illustrations and photo graphs are not to scale consult installation instructions Product designs materials dimensions specifications colors and prices are subject to change or dis...

Страница 11: ...m an improper installation such as this is not covered under the limited warranty Right Side Front Corner Of Fireplace Framing 6 1 4 159 mm 19 5 8 498 mm Step 2 Routing Gas Line Route a 1 2 13 mm gas...

Страница 12: ...places must be vented directly to the outside The vent system may not service multiple appliances and must never be connected to a flue serving a separate solid fuel burning ap pliance The vent pipe i...

Страница 13: ...2 5 0 1 5 7 8 0 0 1 0 0 0 1 5 1 5 2 1 1 1 0 0 0 2 5 9 1 5 2 6 1 2 1 0 0 0 3 1 2 5 7 1 0 2 0 0 0 2 5 2 2 5 7 8 1 0 0 1 0 0 1 5 5 2 5 2 1 2 1 2 0 0 0 3 5 1 3 5 2 6 2 0 3 0 0 0 3 5 4 3 5 7 8 2 0 0 0 1 0...

Страница 14: ...osition is indicated by the alignment of the arrow and dimple as shown in Figure 17 D Install firestop spacer at ceiling When using Secure Vent use SV8BF firestop spacer at ceiling joists If there is...

Страница 15: ...r axis of their initial collar section to align with the required direc tion of the next vent run element Twist elbow sections in a clockwise direction only so as to avoid the possibility of unlocking...

Страница 16: ...own in the figures It is very important that the horizontal inclined run be maintained in a straight no dips slightly elevated plane The recommended incline is approximately 1 4 perfoot 20mmpermeter h...

Страница 17: ...installation of the straight vent sections in horizontal inclined run as described in Step E on Page 14 Install support straps every 3 feet 1914 mm along horizontal inclinedventrunsusingconventional...

Страница 18: ...nded that the Firestop Spacer SV4 5HF be installed on the exterior side of the wall J Assemble vent run to exterior wall If not previously measured locate the center of the vent at the exterior wall P...

Страница 19: ...5 1 37 10 5 3 2 5 5 1 68 12 5 3 8 6 5 1 98 14 5 4 4 7 5 2 3 16 5 5 0 8 5 2 6 18 5 5 6 9 5 2 9 20 6 0 10 3 0 V H 40 feet 12 4 m Max H 20 ft 6 2 m Max HORIZONTAL Vent Figures Tables NOTES Secure Vent c...

Страница 20: ...F Wall Firestop Spacer SV8HF Ceiling Firestop Spacer SV8BF Table D H H1 Maximum V Minimum feet meter feet meter 3 5 1 07 2 5 0 762 6 5 1 98 3 5 1 07 8 5 2 6 4 5 1 37 10 5 3 2 5 5 1 68 12 5 3 8 6 5 1 9...

Страница 21: ...22 1 Cana dian Electrical Code Verify proper operation after servicing S assurer que l appareil fonctionne ad quatement une fois l entretien termin A wiring diagram is provided here for reference purp...

Страница 22: ...REMOTE position Figure 34 7 On the receiver front cover insert the end of a paper clip or other similar object not provided into the hole marked PRG The receiver will beep three times to indicate it i...

Страница 23: ...n accordance with building codes by a quali fied installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation mustbeperformedbyalicensed plumber or...

Страница 24: ...ianceasafe reliableandattractive flame pattern Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Lo...

Страница 25: ...er Engage Logs 3 4 With The Grate Pins And Align Groves At The Bottom Of The Logs Over The Grate 4 3 Engage Log 6 With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Align Hole...

Страница 26: ...e closed position then operate the appliance for a few more minutes to ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the c...

Страница 27: ...ngy If this is problematic or persists as the appliance is continually operated adjust the air shutter closedasdescribedinthepreviousparagraphs Operatetheapplianceforaperiodoftimeasthe effect diminish...

Страница 28: ...e appliance The gray shaded area must be non combustible or Dura Rock Header 2x4 s Spacers Top of Door Frame Fireplace right side Combustible Finished Wall Materials 1 Installations with horizontal te...

Страница 29: ...z lasoigneuse ment pour liminer la poussi re et les traces degraisseoud huile Collezl tiquettesurlebo tier de la t l commande Figure B Choisissez la langue qui est principalement parl e dans la r side...

Страница 30: ...8 SV8FA 1 12 to 7 12 Adjust able Flashing H2259 SV8FB 7 12 to 12 12 Adjustable Flashing H3237 SV8SC6 Storm Collars 6 pack H2260 SV8HF Firestop Spacer Horizontal 3 1 1 spacing H2261 SV8BF Firestop Spac...

Страница 31: ...nce with the manufacturer s instructions and all applicable codes andrequirementsoftheauthorityhavingjurisdiction Iftheinformationin these instruction is not followed exactly a fire explosion or produ...

Страница 32: ...ps Step 14 Attach the conversion label provided in the conversion kit to the rating plate on the appliance Step 15 Apply gas to the system and relight appliance With the main burner ON test the new pr...

Страница 33: ...33 LENNOX HEARTH PRODUCTS MONTEBELLO DLX DIRECT VENT GAS FIREPLACES MDLX40 45 INSTALLATION INSTRUCTIONS NOTES...

Страница 34: ...t notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX...

Отзывы: