LENNOX HEARTH PRODUCTS  •  MONTEBELLO

® 

 DLX DIRECT VENT GAS FIREPLACES (MDLX40/45)  •  INSTALLATION INSTRUCTIONS

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

 

Horizontal terminations have been designed to perform in a wide range of weather condi-

tions. Our terminations meet or exceed industry standards.
When selecting the locations of your horizontal terminations, do not place the termination 

where water from eaves and adjoining rooflines may create a heavy flow of cascading water 

onto the termination cap. If the cap must be placed where the possibility of cascading water 

exists, it is the responsibility of the builder to direct the water away from the termination cap 

by using gutters or other means.
Take care to carefully follow the installation instructions for the termination, including the 

use of silicone caulking where required.

Figure 27 - Installing the Square Horizontal Termination (SV8HTS) 

SV8HTS

Termination

Shown.

13"

(330mm)

8-1/2” 

(216 mm)

(165 mm)

15"

(381 mm)

NOTE: Centerline of Vent Piping is NOT 

the Same as the Centerline of the 

Framed Opening.

  6” to 48” Vent Section,

Telescopic vent section.

Base of Appliance

3"

(76 mm)

Adaptor

SV8RCH

1"

(25 mm)

1"

(25 mm)

6-1/2” 

Figure 28 - Wall Thickness and Horizontal Termination Requirements

u

For wall thicknesses greater than 

    8-1/2", see 

Table 9

u

Siding

Stucco

1-1/4” Maximum Recess of 

Square Termination into 

Exterior Finishing Material    

Exterior Surface of

Framing

5” to 8-1/2” 

(127 to 216 mm)

Exterior Surface of Siding

Minimum wall thickness

5” (127 mm)

Interior Surface of

Finished Wall

Maximum  wall thickness

8-1/2” (216 mm)

SV8HTS

Square Termination

shown

Maximum Extent of Vent 

Run Sections to Exterior

Surface of Framing    

Last Vent Section. Use

Telescopic Vent Section 

(SV8LA), If Necessary

Adaptor

SV8RCH

SV8HTS

Square Termination

Shown

Venting Connection and Exterior Wall Recessing

of the Horizontal Square Termination (SV8HTS).

See 

Figure 12

 on 

Page 10

 for Minimum 

Distance to Base of Appliance

To help minimize water infiltration it 

is recommended that the Firestop/

Spacer (SV4.5HF) be installed on the 

exterior side of the wall.

J.

 

Assemble vent run to exterior wall - 

If not 

previously measured, locate the center of the 

vent at the exterior wall. Prepare an opening as 

described in 

Step B on Page 17

. Assemble the 

vent system to point where the terminus of the 

last section is within 5" (127 mm) to 8-1/2" (216 

mm) inboard of the exterior surface to which 

the SV8HTS termination is to be attached, see 

Figure 29 

and

 Table 9 on Page 19

If the terminus of the last section is not within 

this distance, use the 

telescopic vent section 

SV8LA, 

as the last vent section. For wall thick-

nesses greater than that shown in 

Figure 28

refer to 

Table 9 on Page 19

. This table lists 

the additional venting components needed (in 

addition to the termination and adaptor) for a 

particular range of wall thicknesses.

K.

 

Attach termination adaptor - 

Attach the 

adaptor (adaptor - SV8RCH - provided with the 

termination) to the vent section or telescoping 

vent section), or elbow as shown in 

Figure 27

 

in the same manner as any SV vent component 

(refer to 

Step E on Page 17

).

L.

 

Install Firestop/Spacer at exterior wall  

When using the square

 

termination, install 

SV8HF Firestop/Spacer over the opening at the 

exterior side of the framing, long side up, with 

the 3" spacer clearance at the top as shown in 

Figure 27

, and nail into place.

(The Firestop/Spacer may also be installed over 

the opening at the interior side of the framing).

M. Install the square termination (SV8HTS) 

 For the last step, from outside the exterior 

wall, slide the collars of the termination onto 

the adaptor (the outer over the outer and the 

inner  inside  the  inner)  until  the  termination 

seats against the exterior wall surface to which 

it will be attached. Orient the housing of the 

termination with the arrow pointed upwards. 

Secure the termination to the exterior wall. 

The 

horizontal termination must not be recessed 

into the exterior wall or siding

 

by more than 

the 1-1/4" (32 mm) as shown in

 

Figure 28

.

IMPORTANT: The vent termination is hot 

while in operation and for a period of time 

following the use of the fireplace. Young 

children should be carefully supervised 

when they are in the same area as a hot 

termination.

Содержание Montebello MDLX40IN

Страница 1: ...NE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y TOUCHER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS...

Страница 2: ...eps 9 Typical Installation Sequence 9 Step 1 Framing 9 Fireplace and Framing Specifications 10 Step 2 Routing Gas Line 11 Proper Sizing of Gas Line 11 Step 3 Install the Vent System 12 Vertical Termin...

Страница 3: ...euvent tre n cessaires si les tapis la literie et cetera produisent une quantit importante de pous si re Il est essentiel que les compartiments abritant les commandes les br leurs et les con duits de...

Страница 4: ...aximum Natural Gas 5 5 WC 1 37 kPa 10 5 WC 2 61 kPa Propane 11 0 WC 2 74 kPa 13 0 WC 3 23 kPa Table 2 Manifold Gas Supply Pressure Fuel Low High Natural Gas 1 6 WC 4 kPa 3 5 WC 87 kPa Propane 6 3 WC 1...

Страница 5: ...ted manufactured home and must be installed in accordance with the manu facturer s instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the United States o...

Страница 6: ...Opening H H MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT TERMINATION HEIGHTS FOR VENTS ABOVE FLAT OR SLOPED ROOFS Horizontal Overhang Vertical Wall Vent Termination Storm Collar Concen...

Страница 7: ...mbustion air inlet to any other appliance 6 15 2cm forappliances 10 000BTU hr 3kW 12 30 cm for appliances 10 000 BTU hr 3kW and 100 000 BTU hr 30kW 36 91 cm for appliances 100 000 BTU hr 30kW 6 15 2 c...

Страница 8: ...nce requirements include any projections such as shelves window sills mantels etc above the appliance NOTE We recommend the use of high temperature paint rated 175 F or higher on the underside of the...

Страница 9: ...r wrapper Combustible framing may be in direct contact with the nailing flanges and may be located closer than 1 2 from screw heads and the firebox wrapper in areas adjacent to the nailing flanges Fra...

Страница 10: ...1039 Notes Diagrams illustrations and photo graphs are not to scale consult installation instructions Product designs materials dimensions specifications colors and prices are subject to change or dis...

Страница 11: ...m an improper installation such as this is not covered under the limited warranty Right Side Front Corner Of Fireplace Framing 6 1 4 159 mm 19 5 8 498 mm Step 2 Routing Gas Line Route a 1 2 13 mm gas...

Страница 12: ...places must be vented directly to the outside The vent system may not service multiple appliances and must never be connected to a flue serving a separate solid fuel burning ap pliance The vent pipe i...

Страница 13: ...2 5 0 1 5 7 8 0 0 1 0 0 0 1 5 1 5 2 1 1 1 0 0 0 2 5 9 1 5 2 6 1 2 1 0 0 0 3 1 2 5 7 1 0 2 0 0 0 2 5 2 2 5 7 8 1 0 0 1 0 0 1 5 5 2 5 2 1 2 1 2 0 0 0 3 5 1 3 5 2 6 2 0 3 0 0 0 3 5 4 3 5 7 8 2 0 0 0 1 0...

Страница 14: ...osition is indicated by the alignment of the arrow and dimple as shown in Figure 17 D Install firestop spacer at ceiling When using Secure Vent use SV8BF firestop spacer at ceiling joists If there is...

Страница 15: ...r axis of their initial collar section to align with the required direc tion of the next vent run element Twist elbow sections in a clockwise direction only so as to avoid the possibility of unlocking...

Страница 16: ...own in the figures It is very important that the horizontal inclined run be maintained in a straight no dips slightly elevated plane The recommended incline is approximately 1 4 perfoot 20mmpermeter h...

Страница 17: ...installation of the straight vent sections in horizontal inclined run as described in Step E on Page 14 Install support straps every 3 feet 1914 mm along horizontal inclinedventrunsusingconventional...

Страница 18: ...nded that the Firestop Spacer SV4 5HF be installed on the exterior side of the wall J Assemble vent run to exterior wall If not previously measured locate the center of the vent at the exterior wall P...

Страница 19: ...5 1 37 10 5 3 2 5 5 1 68 12 5 3 8 6 5 1 98 14 5 4 4 7 5 2 3 16 5 5 0 8 5 2 6 18 5 5 6 9 5 2 9 20 6 0 10 3 0 V H 40 feet 12 4 m Max H 20 ft 6 2 m Max HORIZONTAL Vent Figures Tables NOTES Secure Vent c...

Страница 20: ...F Wall Firestop Spacer SV8HF Ceiling Firestop Spacer SV8BF Table D H H1 Maximum V Minimum feet meter feet meter 3 5 1 07 2 5 0 762 6 5 1 98 3 5 1 07 8 5 2 6 4 5 1 37 10 5 3 2 5 5 1 68 12 5 3 8 6 5 1 9...

Страница 21: ...22 1 Cana dian Electrical Code Verify proper operation after servicing S assurer que l appareil fonctionne ad quatement une fois l entretien termin A wiring diagram is provided here for reference purp...

Страница 22: ...REMOTE position Figure 34 7 On the receiver front cover insert the end of a paper clip or other similar object not provided into the hole marked PRG The receiver will beep three times to indicate it i...

Страница 23: ...n accordance with building codes by a quali fied installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation mustbeperformedbyalicensed plumber or...

Страница 24: ...ianceasafe reliableandattractive flame pattern Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Lo...

Страница 25: ...er Engage Logs 3 4 With The Grate Pins And Align Groves At The Bottom Of The Logs Over The Grate 4 3 Engage Log 6 With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Align Hole...

Страница 26: ...e closed position then operate the appliance for a few more minutes to ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the c...

Страница 27: ...ngy If this is problematic or persists as the appliance is continually operated adjust the air shutter closedasdescribedinthepreviousparagraphs Operatetheapplianceforaperiodoftimeasthe effect diminish...

Страница 28: ...e appliance The gray shaded area must be non combustible or Dura Rock Header 2x4 s Spacers Top of Door Frame Fireplace right side Combustible Finished Wall Materials 1 Installations with horizontal te...

Страница 29: ...z lasoigneuse ment pour liminer la poussi re et les traces degraisseoud huile Collezl tiquettesurlebo tier de la t l commande Figure B Choisissez la langue qui est principalement parl e dans la r side...

Страница 30: ...8 SV8FA 1 12 to 7 12 Adjust able Flashing H2259 SV8FB 7 12 to 12 12 Adjustable Flashing H3237 SV8SC6 Storm Collars 6 pack H2260 SV8HF Firestop Spacer Horizontal 3 1 1 spacing H2261 SV8BF Firestop Spac...

Страница 31: ...nce with the manufacturer s instructions and all applicable codes andrequirementsoftheauthorityhavingjurisdiction Iftheinformationin these instruction is not followed exactly a fire explosion or produ...

Страница 32: ...ps Step 14 Attach the conversion label provided in the conversion kit to the rating plate on the appliance Step 15 Apply gas to the system and relight appliance With the main burner ON test the new pr...

Страница 33: ...33 LENNOX HEARTH PRODUCTS MONTEBELLO DLX DIRECT VENT GAS FIREPLACES MDLX40 45 INSTALLATION INSTRUCTIONS NOTES...

Страница 34: ...t notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX...

Отзывы: