41
AUXILIARY DEHUMIDIFIER
The auxiliary dehumidifier setting is used when a
whole home dehumidifier is used for
dehumidification. This requires:
1. Whole home dehumidifier has been wired to
thermostat per dehumidifier installation
instructions.
2. Dehumidification has been enabled on
installer settings
.
3. Unit is in COOL mode, (or if in AUTO, there
has
been at least one thermostat cooling call
made prior to
the dehumidification demand)
.
4. Dehumidification demand exists (RH above
set point).
HUMIDITROL
®
If Humiditrol is enabled in the installer settings,
then this adjustment affects overcooling
operation. Overcooling ranges from 2ºF below the
cooling setpoint (
MIN
setting) down to 2ºF above
the heating setpoint (
MAX
setting). Halfway
between the two settings is the
MID
setting.
If a Humiditrol
®
EDA is installed and enabled, then
the thermostat must be configured to properly
operate the Humiditrol
®
EDA as follows (see
Figure 22 for the Humiditrol
®
EDA operation
flowchart):
Check the HUMIDITY SETTINGS in user settings
to confirm that the user has turned
ON
dehumidification setting.
NOTE - Humiditrol
®
EDA operation requires use
of an outdoor sensor. If sensor is not connected
and Humiditrol
®
EDA is enabled, “OUTDOOR
SENSOR REQUIRED” is displayed in the
information display.
Cooling only
—
Dehumidification will only occur if:
1. Dehumidification demand is present.
2. Cooling demand is not present.
3. Outdoor temperature is less than 95ºF,
4. Indoor temperature is not cooler than 65ºF or
cooler than the heating set point + 2ºF (
IF
the
difference between cooling and heating set
points is greater than the deadband).
In this case, 24VAC is removed from the
D
terminal and
Y1
and
Y2
terminal (if available)
becomes activated with 24VAC. This cycles the
Содержание ComfortSense 7500
Страница 12: ...12 Figure 3 Enhanced Dehumidification Accessory Typical Wiring Diagram ...
Страница 13: ...13 Tc To To Tc Figure 4 CBX32MV XXX 230 06 or Higher and CBX40UHV Wiring Diagrams Condensing Unit Applications ...
Страница 14: ...14 To Tc To Tc Figure 5 CBX32MV XXX 230 06 or Higher and CBX40UHV Wiring Diagrams Heat Pump Unit Applications ...
Страница 18: ...18 TSTAT EL280P TSTAT EL296E EL296V SL280V To Tc To Tc Figure 9 Thermostat Wiring Diagrams continued ...