STAGE 2 HP LOCK TEMP
Default is off (heat pump stage 2 operates
normally). Use this setting in dual fuel applications
to lock in the 2nd stage compressor when the
outdoor temperature is at or less than the LOCK
TEMP set point. Scroll to STAGE 2 HP LOCK
TEMP; touch
ENTER
. Use - + option to select a
LOCK TEMP between -40 and 75ºF. Touch
<
to
return to previous menu.
Configuration
Figures
Multi-stage Cooling for Heat Pump/Non-Heat Pump
14
Heating - Non-Heat Pump (1 or 2 stages)
15
Heating - Heat Pump with NO backup heat
10
Heating - Heat Pump w/electric heat (2-stage: 1compr/1backup)
10
Heating - Heat Pump w/electric heat (3 stage: 2compr/1backup)
11
Heating - Heat Pump w/electric heat (3 stage: 1compr/2backup)
11
Heating - Heat Pump w/electric heat (4 stage: 2compr/2backup)
12
Heating - dual fuel (2-stage: 1compr/1backup)
13
Heating - dual fuel (3 stage: 1compr/2backup)
14
Heating - dual fuel (3 stage: 2compr/1backup)
15
Heating - dual fuel (4 stage: 2compr/2backup)
16
Содержание ComfortSense 7500
Страница 12: ...12 Figure 3 Enhanced Dehumidification Accessory Typical Wiring Diagram ...
Страница 13: ...13 Tc To To Tc Figure 4 CBX32MV XXX 230 06 or Higher and CBX40UHV Wiring Diagrams Condensing Unit Applications ...
Страница 14: ...14 To Tc To Tc Figure 5 CBX32MV XXX 230 06 or Higher and CBX40UHV Wiring Diagrams Heat Pump Unit Applications ...
Страница 18: ...18 TSTAT EL280P TSTAT EL296E EL296V SL280V To Tc To Tc Figure 9 Thermostat Wiring Diagrams continued ...