![Lennox ComfortSense 7500 Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/lennox/comfortsense-7500/comfortsense-7500_installation-and-setup-manual_1878096039.webp)
39
Rh
set point
=
Outdoor Temp (ºF)
2
+ 25
+
RH
user dew point
adjustment
Where:
RH
user dew point adjustment
cannot /-15% and
Rh
setpoint
minimum is 15% and cannot exceed 45%.
DEW POINT NORMAL & MAX
Dew point adjustment mode will change the
humidification set point based on the outdoor
temperature and a user-defined dew point
adjustment setting.
NOTE - In dew point adjustment mode, the
humidification set point has no effect whatsoever
on unit operation. Only the user-defined dew point
adjustment setting affects operation per the
following the above formula.
Dehumidify
Dehumidification
(removing moisture from air) can
occur only when the thermostat is in
cool mode
.
When a dehumidification demand is present, a
dehumidification signal (0VAC - open circuit) is
present at the D terminal. This is used to reduce
the speed of the indoor blower during
dehumidification. At the same time, the Y1 and Y2
(if available) terminals become activated with
24VAC. The H terminal is inactive (0VAC - open
circuit) during dehumidification.
System must be in cool mode and had one call for
AC before feature is active. Once dehumidification
is active the dehumidification modes are as
follows:
Normal:
Runs dehumidification with a call for
cooling and dehumidification.
Max:
Runs dehumidification with a
dehumidification call but without a call for
cooling.
Auxiliary Dehumidifier:
Runs based on
humidity reading from thermostat's internal
humidity sensor and will call for
dehumidification using the auxiliary
dehumidifier (whole house dehumidifier).
Содержание ComfortSense 7500
Страница 12: ...12 Figure 3 Enhanced Dehumidification Accessory Typical Wiring Diagram ...
Страница 13: ...13 Tc To To Tc Figure 4 CBX32MV XXX 230 06 or Higher and CBX40UHV Wiring Diagrams Condensing Unit Applications ...
Страница 14: ...14 To Tc To Tc Figure 5 CBX32MV XXX 230 06 or Higher and CBX40UHV Wiring Diagrams Heat Pump Unit Applications ...
Страница 18: ...18 TSTAT EL280P TSTAT EL296E EL296V SL280V To Tc To Tc Figure 9 Thermostat Wiring Diagrams continued ...