AQUA
4
–AGU-1405-E
- 20 -
Power supply
400 / 3+N / 50
Maximum absorbed current (FLA) [without options]
A
41
44
51
55
66
Start up current (LRA) [without options]
A
159
162
185
183
191
Start up current with soft starter [without options]
A
104
105
121
119
124
Number of fans
4
4
6
6
6
Air flow
m3/h
21379
21379
30913
30913
30913
Absorbed power of fans
kW
1.2
1.2
1.8
1.8
1.8
Absorbed current of fans
A
4.4
4.4
6.6
6.6
6.6
Sound power level Lw
db(A)
79
79
80
80
80
Sound pressure level Lp @ 10 m Q=2
db(A)
51
51
52
52
52
Compressors / Circuits
2/2
2/2
2/2
2/2
2/2
Water tank volume (option)
l
200
220
Dimensions [LxWxH]
mm
2510 x 1183 x 1735 2862 x 1183 x 1735
Weight [without options]
kg
680
690
800
810
850