AQUA
4
–AGU-1405-E
- 8 -
Options
Features and Benefits
Antifreeze protection
Antifreeze protection on exchangers and pipes
Electrical trace heating and reinforced insulation on the both braze
plate heat exchangers and pipes.
Antifreeze protection on exchangers, pipes, pump(s) and
expansion vessel
Electrical trace heating and reinforced insulation on the brazed
plate heat exchangers, pipess, pump(s) and the expansion vessel.
Antifreeze protection on exchangers, pipes, pump(s), expansion
vessel and water tank
Electrical trace heating and reinforced insulation on the both
brazed plate heat exchangers, pipes, pump(s), expansion vessel
and the water tank.
Condensing control
Electronically controlled modulating fan speed with EC motors
Remote Control
Remote display (supplied loose)
PGD1 user interface allows performance of all operations of the
program, displaying the status of the unit and changing settings. It
can be located up to a maximum of 50 meters from the unit with a
standard telephone cable and up to a maximum of 200 meters
from the unit with a shielded cable.
Control interface
Modbus communication interface RS485
Communication card using ModBus or Carel protocol RS485.
Communication interface with a building management system.
LonWorks® communication interface FTT10
Communication card using LonWorks® FTT10. Communication
interface with a building management system.
pCOweb - Modbus/BACnet/SNMP communication interface
TCP/IP
Communication card using Modbus/BACnet®/SNMP TCP/IP.
Communication interface with a building management system.
Anti-vibration isolation
Rubber anti-vibration mounts (supplied loose)
4 or 8 rubber anti-vibration isolators are supplied depending on the
type of unit. They will be inserted between the floor and the unit to
prevent vibration.
Spring anti-vibration mounts (supplied loose)
4 or 8 spring anti-vibration isolators are supplied depending on the
type of unit. They will be inserted between the floor and the unit to
prevent vibration.
Содержание AAH041
Страница 1: ...lennoxemeia com AQUA4 AAH APPLICATION GUIDE Polyvalent air cooled heat pump 50 330 kW AQUA4 AGU 1405 E...
Страница 2: ......
Страница 13: ...AQUA4 AGU 1405 E 11 Example of 2 pipe installation for Hotel and Hospital...
Страница 20: ...AQUA4 AGU 1405 E 18 Nb of compressor 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4...
Страница 45: ...AQUA4 AGU 1405 E 43 AAH PS PL MS ML 094 and 104 Box F3 AAH PS PL MS ML 124 144 164 and 194 Box F4...
Страница 46: ...AQUA4 AGU 1405 E 44 AAH PS PL MS ML 214 and 244 Box F5 AAH PS PL MS ML 274 294 and 324 Box F6...