14ACX - 1.5 to 5 Ton Air Conditioner / Page 115
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS042-230A
TXV
42,000
15.50
12.50
CH33-49
SL280UH090XV60C
7627640
14ACXS042-230A
TXV
42,000
15.50
12.50
CH33-49
SL280UH110V60C
7782989
14ACXS042-230A
TXV
42,000
15.50
12.50
CH33-49
SL280UH110XV60C
7627644
14ACXS042-230A
TXV
41,500
15.50
12.50
CH33-49
SLP98UH090XV36C
7782990
14ACXS042-230A
TXV
42,000
15.50
12.50
CH33-49
SLP98UH090XV48C
7627647
14ACXS042-230A
TXV
42,000
15.50
12.50
CH33-49
SLP98UH090XV60C
7782991
14ACXS042-230A
TXV
42,000
15.50
12.50
CH33-49
SLP98UH110XV60C
7627650
14ACXS042-230A
TXV
42,000
14.00
12.20
CH33-49
7627618
14ACXS042-230A
TXV
41,500
15.50
12.50
CH33-50/60C
EL180UH090E60C
7782993
14ACXS042-230A
TXV
41,500
15.50
12.50
CH33-50/60C
EL180UH110E60C
7627658
14ACXS042-230A
TXV
41,500
15.50
12.50
CH33-50/60C
EL180UH110XE60C
7627661
14ACXS042-230A
TXV
41,500
15.50
12.50
CH33-50/60C
EL195UH090XE48C
7627663
14ACXS042-230A
TXV
42,000
15.50
12.50
CH33-50/60C
EL195UH110XE60C
7627666
14ACXS042-230A
TXV
41,500
15.50
12.50
CH33-50/60C
EL296UH090XE48C
7627669
14ACXS042-230A
TXV
41,500
15.10
12.50
CH33-50/60C
EL296UH090XV36C
7627672
14ACXS042-230A
TXV
41,500
15.50
12.50
CH33-50/60C
EL296UH090XV48C
7782994
14ACXS042-230A
TXV
42,000
15.10
12.50
CH33-50/60C
EL296UH090XV60C
7627675
14ACXS042-230A
TXV
42,000
15.50
12.50
CH33-50/60C
EL296UH110XE60C
7782995
14ACXS042-230A
TXV
41,500
15.50
12.50
CH33-50/60C
EL296UH110XV48C
7627678
14ACXS042-230A
TXV
41,500
15.50
12.50
CH33-50/60C
EL296UH110XV60C
7782996
14ACXS042-230A
TXV
42,000
15.50
12.50
CH33-50/60C
SL280UH090V60C
7627681
14ACXS042-230A
TXV
42,000
15.50
12.50
CH33-50/60C
SL280UH090XV60C
7782997
14ACXS042-230A
TXV
41,500
15.50
12.50
CH33-50/60C
SL280UH110V60C
7627684
14ACXS042-230A
TXV
41,500
15.50
12.50
CH33-50/60C
SL280UH110XV60C
7782998
14ACXS042-230A
TXV
41,500
15.10
12.50
CH33-50/60C
SLP98UH090XV36C
7627688
14ACXS042-230A
TXV
41,500
15.50
12.50
CH33-50/60C
SLP98UH090XV48C
7782999
14ACXS042-230A
TXV
42,000
15.10
12.50
CH33-50/60C
SLP98UH090XV60C
7627691
14ACXS042-230A
TXV
41,500
15.50
12.50
CH33-50/60C
SLP98UH110XV60C
7783000
14ACXS042-230A
TXV
41,500
14.00
12.20
CH33-50/60C
7627654
14ACXS042-230A
TXV
42,000
15.50
12.50
CH35-42B
EL180UH090E48B
7627694
14ACXS042-230A
TXV
42,000
15.50
12.50
CH35-42B
EL180UH090XE48B
7783001
14ACXS042-230A
TXV
42,000
15.10
12.50
CH35-42B
EL296UH045XV36B
7627697
14ACXS042-230A
TXV
41,500
15.00
12.50
CH35-42B
EL296UH070XV36B
7783002
14ACXS042-230A
TXV
42,000
15.50
12.50
CH35-42B
SL280UH090V36B
7627700
14ACXS042-230A
TXV
42,000
15.50
12.50
CH35-42B
SL280UH090V48B
7783003
14ACXS042-230A
TXV
42,000
15.50
12.50
CH35-42B
SL280UH090XV48B
7627704
14ACXS042-230A
TXV
41,500
15.00
12.50
CH35-42B
SLP98UH070XV36B
7783004
14ACXS042-230A
TXV
41,500
14.25
12.00
CH35-42B
8341995
14ACXS042-230A
TXV
41,500
15.50
12.50
CH35-42C
EL180UH090E60C
7783005
14ACXS042-230A
TXV
41,500
15.50
12.50
CH35-42C
EL180UH110E60C
7627710
14ACXS042-230A
TXV
41,500
15.50
12.50
CH35-42C
EL180UH110XE60C
7783006
14ACXS042-230A
TXV
41,500
15.50
12.50
CH35-42C
EL195UH090XE48C
7627713
14ACXS042-230A
TXV
42,000
15.50
12.50
CH35-42C
EL195UH110XE60C
7783007
14ACXS042-230A
TXV
41,500
15.50
12.50
CH35-42C
EL296UH090XE48C
7627716
14ACXS042-230A
TXV
41,500
15.50
12.50
CH35-42C
EL296UH090XV36C
7783008
14ACXS042-230A
TXV
41,500
15.50
12.50
CH35-42C
EL296UH090XV48C
7627719
14ACXS042-230A
TXV
42,000
15.50
12.50
CH35-42C
EL296UH090XV60C
7783009
14ACXS042-230A
TXV
42,000
15.50
12.50
CH35-42C
EL296UH110XE60C
7627722
14ACXS042-230A
TXV
41,500
15.50
12.50
CH35-42C
EL296UH110XV48C
7783010
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.