14ACX - 1.5 to 5 Ton Air Conditioner / Page 131
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-024-230A
TXV
23,000
15.10
12.50
C33-30B
EL195UH045XE36B
7174547
14ACX-024-230A
TXV
23,400
15.50
12.50
C33-30B
EL195UH070XE36B
7174548
14ACX-024-230A
TXV
23,000
15.10
12.50
C33-30B
EL296UH045XE36B
7174549
14ACX-024-230A
TXV
23,600
15.50
12.50
C33-30B
EL296UH045XV36B
7174551
14ACX-024-230A
TXV
23,400
15.50
12.50
C33-30B
EL296UH070XE36B
7174550
14ACX-024-230A
TXV
23,600
15.50
12.50
C33-30B
EL296UH070XV36B
7174552
14ACX-024-230A
TXV
23,600
15.10
13.00
C33-30B
SL280UH090V36B
7174542
14ACX-024-230A
TXV
23,600
15.10
12.50
C33-30B
SL280UH090V48B
7174543
14ACX-024-230A
TXV
23,600
15.10
12.50
C33-30B
SL280UH090XV48B
7174544
14ACX-024-230A
TXV
23,600
15.50
12.50
C33-30B
SLP98UH070XV36B
7174553
14ACX-024-230A
TXV
23,600
16.00
13.00
C33-30C
EL296UH090XV36C
7174554
14ACX-024-230A
TXV
23,600
16.00
13.00
C33-30C
SLP98UH090XV36C
7174555
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31A
EL180UH045E36A
7174559
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31A
EL180UH045XE36A
7174560
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31A
SL280UH070V36A
7174557
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31A
SL280UH070XV36A
7174558
14ACX-024-230A
TXV
24,000
14.50
12.20
C33-31A
7174556
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
EL180UH070E36B
7174565
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
EL180UH070XE36B
7174566
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
EL195UH030XE24B
8608846
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
EL195UH045XE24B
8608847
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
EL195UH045XE36B
7174567
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
EL195UH070XE36B
7174568
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
EL296UH045XE36B
7174569
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
EL296UH045XV36B
7174571
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
EL296UH070XE36B
7174570
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
EL296UH070XV36B
7174572
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
SL280UH090V36B
7174562
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
SL280UH090V48B
7174563
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
SL280UH090XV48B
7174564
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-31B
SLP98UH070XV36B
7174573
14ACX-024-230A
TXV
24,000
14.50
12.20
C33-31B
7174561
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-36A
EL180UH045E36A
7174579
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-36A
EL180UH045XE36A
7174580
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-36A
SL280UH070V36A
7174577
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-36A
SL280UH070XV36A
7174578
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-36B
EL180UH070E36B
7174584
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-36B
EL180UH070XE36B
7174585
14ACX-024-230A
TXV
24,000
15.50
12.50
C33-36B
EL195UH030XE24B
8608848
14ACX-024-230A
TXV
24,000
15.50
12.50
C33-36B
EL195UH045XE24B
8608849
14ACX-024-230A
TXV
23,400
15.50
12.50
C33-36B
EL195UH045XE36B
7174586
14ACX-024-230A
TXV
23,600
16.00
13.00
C33-36B
EL195UH070XE36B
7174587
14ACX-024-230A
TXV
23,400
15.50
12.50
C33-36B
EL296UH045XE36B
7174588
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-36B
EL296UH045XV36B
7174590
14ACX-024-230A
TXV
23,600
16.00
13.00
C33-36B
EL296UH070XE36B
7174589
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-36B
EL296UH070XV36B
7174591
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-36B
SL280UH090V36B
7174581
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-36B
SL280UH090V48B
7174582
14ACX-024-230A
TXV
24,000
16.00
13.00
C33-36B
SL280UH090XV48B
7174583
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.