AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS024-230A
TXV
23,600
16.00
13.00
C33-30C
SLP98UH090XV36C
7624587
14ACXS024-230A
TXV
23,000
14.00
11.50
C33-30C
7624557
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31A
EL180UH045E36A
7624593
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31A
EL180UH045XE36A
7624595
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31A
SL280UH070V36A
7624590
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31A
SL280UH070XV36A
7624592
14ACXS024-230A
TXV
24,000
14.50
12.20
C33-31A
7624588
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
EL180UH070E36B
7624603
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
EL180UH070XE36B
7624605
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
EL195UH030XE24B
8606529
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
EL195UH045XE24B
8606531
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
EL195UH045XE36B
7624607
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
EL195UH070XE36B
7624608
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
EL296UH045XE36B
7624610
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
EL296UH045XV36B
7624613
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
EL296UH070XE36B
7624611
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
EL296UH070XV36B
7624615
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
SL280UH090V36B
7624598
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
SL280UH090V48B
7624600
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
SL280UH090XV48B
7624602
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-31B
SLP98UH070XV36B
7624616
14ACXS024-230A
TXV
24,000
14.50
12.20
C33-31B
7624597
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36A
EL180UH045E36A
7624627
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36A
EL180UH045XE36A
7624628
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36A
SL280UH070V36A
7624623
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36A
SL280UH070XV36A
7624625
14ACXS024-230A
TXV
23,800
14.50
12.00
C33-36A
7624618
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36B
EL180UH070E36B
7624635
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36B
EL180UH070XE36B
7624636
14ACXS024-230A
TXV
24,000
15.50
12.50
C33-36B
EL195UH030XE24B
8606532
14ACXS024-230A
TXV
24,000
15.50
12.50
C33-36B
EL195UH045XE24B
8606534
14ACXS024-230A
TXV
23,400
15.50
12.50
C33-36B
EL195UH045XE36B
7624638
14ACXS024-230A
TXV
23,600
16.00
13.00
C33-36B
EL195UH070XE36B
7624640
14ACXS024-230A
TXV
23,400
15.50
12.50
C33-36B
EL296UH045XE36B
7624641
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36B
EL296UH045XV36B
7624644
14ACXS024-230A
TXV
23,600
16.00
13.00
C33-36B
EL296UH070XE36B
7624643
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36B
EL296UH070XV36B
7624646
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36B
SL280UH090V36B
7624630
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36B
SL280UH090V48B
7624631
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36B
SL280UH090XV48B
7624633
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36B
SLP98UH070XV36B
7624648
14ACXS024-230A
TXV
23,800
14.50
12.00
C33-36B
7624620
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36C
EL296UH090XV36C
7624649
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-36C
SLP98UH090XV36C
7624651
14ACXS024-230A
TXV
23,800
14.50
12.00
C33-36C
7624622
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-38A
EL180UH045E36A
7624658
14ACXS024-230A
TXV
24,000
16.00
13.00
C33-38A
EL180UH045XE36A
7624659
14ACXS024-230A
TXV
24,000
16.00
13.50
C33-38A
SL280UH070V36A
7624654
14ACXS024-230A
TXV
24,000
16.00
13.50
C33-38A
SL280UH070XV36A
7624656
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.