14ACX - 1.5 to 5 Ton Air Conditioner / Page 125
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-018-230A
RFC
19,000
14.00
12.20
C33-31A
7186906
14ACX-018-230A
RFC
19,000
14.00
12.20
C33-31B
7186910
14ACX-018-230A
RFC
18,000
14.00
12.20
C35-18/24A
8471005
14ACX-018-230A
RFC
18,000
14.00
12.20
C35-18/24B
8471006
14ACX-018-230A
RFC
19,200
14.25
12.20
CH33-31A
7186942
14ACX-018-230A
RFC
19,100
14.25
12.20
CH33-31B
7186946
14ACX-018-230A
RFC
19,000
14.00
12.20
CR33-30/36A
7186983
14ACX-018-230A
RFC
19,000
14.00
12.20
CR33-30/36B
7186986
14ACX-018-230A
TXV
18,200
14.50
12.50
C33-18
EL180UH045E36A
7186877
14ACX-018-230A
TXV
18,200
14.50
12.50
C33-18
EL180UH045XE36A
7186876
14ACX-018-230A
TXV
19,500
16.00
13.00
C33-19
EL180UH045E36A
7186880
14ACX-018-230A
TXV
19,500
16.00
13.00
C33-19
EL180UH045XE36A
7186879
14ACX-018-230A
TXV
18,400
15.00
12.50
C33-24A
EL180UH045E36A
7186882
14ACX-018-230A
TXV
18,400
15.00
12.50
C33-24A
EL180UH045XE36A
7186881
14ACX-018-230A
TXV
18,500
14.50
12.20
C33-24B
EL180UH070E36B
7186884
14ACX-018-230A
TXV
18,500
14.50
12.20
C33-24B
EL180UH070XE36B
7186883
14ACX-018-230A
TXV
18,000
14.50
12.50
C33-24B
EL195UH030XE24B
8608812
14ACX-018-230A
TXV
18,000
14.50
12.50
C33-24B
EL195UH045XE24B
8608813
14ACX-018-230A
TXV
18,600
14.50
12.50
C33-24B
EL195UH045XE36B
7186885
14ACX-018-230A
TXV
18,600
14.50
12.50
C33-24B
EL296UH045XE36B
7186886
14ACX-018-230A
TXV
19,700
16.00
13.00
C33-25A
EL180UH045E36A
7186890
14ACX-018-230A
TXV
19,700
16.00
13.00
C33-25A
EL180UH045XE36A
7186889
14ACX-018-230A
TXV
19,200
14.25
12.20
C33-25A
7186888
14ACX-018-230A
TXV
19,500
15.50
12.50
C33-25B
EL180UH070E36B
7186894
14ACX-018-230A
TXV
19,500
15.50
12.50
C33-25B
EL180UH070XE36B
7186893
14ACX-018-230A
TXV
18,000
15.50
12.50
C33-25B
EL195UH030XE24B
8608814
14ACX-018-230A
TXV
18,000
15.50
12.50
C33-25B
EL195UH045XE24B
8608815
14ACX-018-230A
TXV
20,000
16.00
13.00
C33-25B
EL195UH045XE36B
7186895
14ACX-018-230A
TXV
20,000
16.00
13.00
C33-25B
EL296UH045XE36B
7186896
14ACX-018-230A
TXV
20,200
16.00
13.00
C33-25B
EL296UH045XV36B
7186897
14ACX-018-230A
TXV
20,200
16.00
13.00
C33-25B
EL296UH070XV36B
7614659
14ACX-018-230A
TXV
20,200
16.00
13.00
C33-25B
SLP98UH070XV36B
7523952
14ACX-018-230A
TXV
19,200
14.25
12.20
C33-25B
7186892
14ACX-018-230A
TXV
19,100
15.50
12.50
C33-30A
EL180UH045E36A
7186899
14ACX-018-230A
TXV
19,100
15.50
12.50
C33-30A
EL180UH045XE36A
7186900
14ACX-018-230A
TXV
18,900
15.00
12.50
C33-30B
EL180UH070E36B
7186901
14ACX-018-230A
TXV
18,900
15.00
12.50
C33-30B
EL180UH070XE36B
7186902
14ACX-018-230A
TXV
18,000
15.10
12.50
C33-30B
EL195UH030XE24B
8608816
14ACX-018-230A
TXV
18,000
15.10
12.50
C33-30B
EL195UH045XE24B
8608817
14ACX-018-230A
TXV
18,900
15.10
12.50
C33-30B
EL195UH045XE36B
7186903
14ACX-018-230A
TXV
18,900
15.10
12.50
C33-30B
EL296UH045XE36B
7186904
14ACX-018-230A
TXV
19,500
16.00
13.00
C33-30B
EL296UH045XV36B
7186905
14ACX-018-230A
TXV
19,900
16.00
13.00
C33-31A
EL180UH045E36A
7186908
14ACX-018-230A
TXV
19,900
16.00
13.00
C33-31A
EL180UH045XE36A
7186909
14ACX-018-230A
TXV
19,300
14.50
12.20
C33-31A
7186907
14ACX-018-230A
TXV
19,700
15.50
12.50
C33-31B
EL180UH070E36B
7186912
14ACX-018-230A
TXV
19,700
15.50
12.50
C33-31B
EL180UH070XE36B
7186913
14ACX-018-230A
TXV
18,000
16.00
13.00
C33-31B
EL195UH030XE24B
8608818
14ACX-018-230A
TXV
18,000
16.00
13.00
C33-31B
EL195UH045XE24B
8608819
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.