14ACX - 1.5 to 5 Ton Air Conditioner / Page 163
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-036-230A
TXV
34,600
15.10
12.50
CH33-31B
EL180UH070E36B
7510461
14ACX-036-230A
TXV
34,600
15.10
12.50
CH33-31B
EL180UH070XE36B
7510462
14ACX-036-230A
TXV
34,600
15.50
12.50
CH33-31B
EL180UH090E48B
7510463
14ACX-036-230A
TXV
34,600
15.50
12.50
CH33-31B
EL180UH090XE48B
7510464
14ACX-036-230A
TXV
34,200
14.50
12.20
CH33-31B
EL195UH045XE36B
7510465
14ACX-036-230A
TXV
34,400
15.00
12.50
CH33-31B
EL195UH070XE36B
7510467
14ACX-036-230A
TXV
34,200
14.50
12.20
CH33-31B
EL296UH045XE36B
7510466
14ACX-036-230A
TXV
34,600
15.10
12.50
CH33-31B
EL296UH045XV36B
7510469
14ACX-036-230A
TXV
34,400
15.00
12.50
CH33-31B
EL296UH070XE36B
7510468
14ACX-036-230A
TXV
34,600
15.10
12.50
CH33-31B
EL296UH070XV36B
7510470
14ACX-036-230A
TXV
34,800
16.00
13.00
CH33-31B
SL280UH090V36B
7510458
14ACX-036-230A
TXV
34,800
15.50
12.50
CH33-31B
SL280UH090V48B
7510459
14ACX-036-230A
TXV
34,800
15.50
12.50
CH33-31B
SL280UH090XV48B
7510460
14ACX-036-230A
TXV
34,600
15.10
12.50
CH33-31B
SLP98UH070XV36B
7510471
14ACX-036-230A
TXV
34,200
14.50
12.20
CH33-31B
7510457
14ACX-036-230A
TXV
33,000
14.50
12.20
CH33-36A
EL180UH045E36A
7510474
14ACX-036-230A
TXV
33,000
14.50
12.20
CH33-36A
EL180UH045XE36A
7510475
14ACX-036-230A
TXV
33,200
14.50
12.20
CH33-36A
SL280UH070V36A
7510472
14ACX-036-230A
TXV
33,200
14.50
12.20
CH33-36A
SL280UH070XV36A
7510473
14ACX-036-230A
TXV
33,400
15.50
12.50
CH33-36B
EL180UH070E36B
7510480
14ACX-036-230A
TXV
33,400
15.50
12.50
CH33-36B
EL180UH070XE36B
7510481
14ACX-036-230A
TXV
33,400
15.10
12.50
CH33-36B
EL180UH090E48B
7510482
14ACX-036-230A
TXV
33,400
15.10
12.50
CH33-36B
EL180UH090XE48B
7510483
14ACX-036-230A
TXV
33,000
15.00
12.50
CH33-36B
EL195UH045XE36B
7510484
14ACX-036-230A
TXV
33,200
15.00
12.50
CH33-36B
EL195UH070XE36B
7510486
14ACX-036-230A
TXV
33,000
15.00
12.50
CH33-36B
EL296UH045XE36B
7510485
14ACX-036-230A
TXV
33,400
14.50
12.20
CH33-36B
EL296UH045XV36B
7513173
14ACX-036-230A
TXV
33,200
15.00
12.50
CH33-36B
EL296UH070XE36B
7510487
14ACX-036-230A
TXV
33,400
15.00
12.50
CH33-36B
EL296UH070XV36B
7510488
14ACX-036-230A
TXV
33,400
15.50
12.50
CH33-36B
SL280UH090V36B
7510477
14ACX-036-230A
TXV
33,600
15.50
12.50
CH33-36B
SL280UH090V48B
7510478
14ACX-036-230A
TXV
33,600
15.50
12.50
CH33-36B
SL280UH090XV48B
7510479
14ACX-036-230A
TXV
33,400
15.00
12.50
CH33-36B
SLP98UH070XV36B
7510489
14ACX-036-230A
TXV
33,800
15.50
12.50
CH33-36C
EL180UH090E60C
7510493
14ACX-036-230A
TXV
33,800
15.50
12.50
CH33-36C
EL180UH110E60C
7510494
14ACX-036-230A
TXV
33,800
15.50
12.50
CH33-36C
EL180UH110XE60C
7510495
14ACX-036-230A
TXV
33,600
15.10
12.50
CH33-36C
EL195UH090XE48C
7510496
14ACX-036-230A
TXV
34,000
15.50
12.50
CH33-36C
EL195UH110XE60C
7510498
14ACX-036-230A
TXV
33,600
15.10
12.50
CH33-36C
EL296UH090XE48C
7510497
14ACX-036-230A
TXV
34,000
15.50
12.50
CH33-36C
EL296UH090XV36C
7510500
14ACX-036-230A
TXV
33,800
15.50
12.50
CH33-36C
EL296UH090XV48C
7510502
14ACX-036-230A
TXV
34,000
15.50
12.50
CH33-36C
EL296UH110XE60C
7510499
14ACX-036-230A
TXV
34,000
15.50
12.50
CH33-36C
EL296UH110XV48C
7510504
14ACX-036-230A
TXV
34,200
15.50
12.50
CH33-36C
EL296UH110XV60C
7510505
14ACX-036-230A
TXV
34,400
15.50
12.50
CH33-36C
SL280UH090V60C
7513175
14ACX-036-230A
TXV
34,400
15.50
12.50
CH33-36C
SL280UH090XV60C
7513177
14ACX-036-230A
TXV
34,200
15.50
12.50
CH33-36C
SL280UH110V60C
7510491
14ACX-036-230A
TXV
34,200
15.50
12.50
CH33-36C
SL280UH110XV60C
7510492
14ACX-036-230A
TXV
34,000
15.50
12.50
CH33-36C
SLP98UH090XV36C
7510501
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.