Faults
140
Code Group Description Possible
cause Remedies
A05
Information
Minimum fill level
reached
Remaining quan-
tity reached
Incorrect entry
Possible incorrect
sensor value for
electronic fill level
indicator
Refill
Correct the entry
Check the sen-
sor
A06 Information
Maximum
spray
pressure setting
reached
Incorrect entry
Possible sensor
fault
Spraying fault
Correct the entry
Reduce spray
pressure
A07 Information
Minimum
spray
pressure setting
reached
Incorrect entry
Possible sensor
fault
Spraying fault
Correct the entry
Increase spray
pressure
A08 Fault
Difference
be-
tween the target
and actual distri-
bution rate in l/ha
when control
valve opening
Control valve not
working
Driving speed too
high
Visual check of
control valve
Reduce driving
speed
Keep within the
control range
A09 Fault
Pressure
sensor
signal faulty
Cable fault
Sensor fault
Check the wiring
Check the sen-
sor
A10
Fault
Fill level sensor
signal faulty
Cable fault
Sensor fault
Check the wiring
Check the sen-
sor
A11 Fault
Defective
sensor
S5 on arm 1, left
Cable fault
Sensor fault
Check the wiring
Check the sen-
sor
A12 Fault
Defective
sensor
S6 on arm 1, right
Cable fault
Sensor fault
Check the wiring
Check the sen-
sor
A13 Fault
Lift
mast
height
sensor S4 defec-
tive
Cable fault
Sensor fault
Check the wiring
Check the sen-
sor
A14 Fault
Slope
position
sensor S2 defec-
tive
Cable fault
Sensor fault
Check the wiring
Check the sen-
sor
A15
Information
Sensor S15 / S16
of flow monitor
shows no flow or
flow in both direc-
Control unit not
activated
Sensor defective
Check the oil
supply
Check the sen-
sor