Faults
145
18.6
D – System fault
These vary according to the version of the implement.
Code Description
Possible
cause
Remedies
D01 CAN-BUS
fault
Connecting plug missing
Defective bus cable
Defective job computer plug
connector
Defective operating terminal
plug connector
Visual inspection
Replace cable if necessa-
ry
Replace job computer if
necessary
Replace operating termi-
nal if necessary
D02
LIN-BUS 1 (job
computer) fault
Defective bus cable
Defective job computer plug
connector
Defective LIN accessory
plug connector
Visual inspection
Replace cable if necessa-
ry
Replace plug connector if
necessary
Replace accessory if ne-
cessary
D03
LIN-BUS 2 (oper-
ating terminal)
fault
Defective bus cable
Defective operating terminal
plug connector
Defective LIN accessory
plug connector
Visual inspection
Replace cable if necessa-
ry
Replace plug connector if
necessary
Replace accessory if ne-
cessary
D04
Emergency stop
chain interrupted
Connecting plug missing
Defective bus cable
Defective job computer plug
connector
Defective operating terminal
plug connector
Visual inspection
Replace cable if necessa-
ry
Replace plug connector if
necessary
D05 Low voltage fault
Incorrect or faulty supply volt-
age
Check power supply
D06 High
voltage
fault
Incorrect or faulty supply volt-
age
Check power supply
D07
Job computer
temperature fault
Overheating
Look for the cause of over-
heating