Faults
139
18.2.2 Categories B to D
Press this function key to deactivate the
message.
The deactivated messages are displayed
again after a restart of the Ecospray oper-
ating terminal.
Once the fault has been remedied, the red
LED goes out.
18.3
A – Warning/Fault/Information
These vary according to the version of the implement.
Code Group Description Possible
cause Remedies
A01 Warning Difference
be-
tween the length
of width section
and the working
width
Incorrect entry
Correct the entry
A02 Fault
Difference
be-
tween target and
actual distribution
rate in l/ha when
control valve clos-
ing
Control valve not
working
Driving speed too
slow
Pressure filter
dirty
Visual check of
control valve
Increase driving
speed
Keep within the
control range
Clean pressure
filter
A03 Fault
Both
pendulum
lock sensors are
activated
Cable fault
Sensor fault
Incorrect sensor
switching dis-
tance
Visual check of
wiring
Visual check of
sensors
Check the sen-
sor switching
distance
A04 Information
Maximum
fill
level
reached
Overfilling
Incorrect entry
Possible incorrect
sensor value for
electronic fill level
indicator
Correct the entry