Operation
132
16.6 Nozzle
cleaning
menu
Switch on the operating terminal.
The first basic menu is displayed.
Press this key.
The second basic menu is displayed.
Press this key to access the nozzle
cleaning menu.
For automatic nozzle cleaning, the boom must be unfolded, the
PTO switched on and the main tank already cleaned; refer to the
operating instructions for the implement.
Press this key to start automatic nozzle
cleaning.
The LED for this key flashes during this
function.
The cleaning program automatically moves
through all the segments and finishes after
cleaning the last segment.
If you press this key during the proce-
dure, the process ends.