Operation
115
16.2.7 Proportional valve settings (only in Comfort and Premium)
The viscosity of the oil may vary depending on the tractor and environmental fac-
tors; as a result it may be necessary to change the proportional valve settings.
Press this key in the second window of
the settings menu to access the propor-
tional valve settings menu.
Parameters can be changed if malfunc-
tions occur in relation to the target posi-
tions.
The MIN value is responsible for moving to
the target position.
Increase the MIN value if the target posi-
tion is not reached.
Reduce the MIN value if the target posi-
tion is exceeded.
The MAX value sets the maximum speed
for the full travel distance.
Increase the MAX value if the speed is
too slow.
Reduce the MAX value if the speed is
too high.
Press the rotary encoder to activate se-
lection.
Press the rotary encoder to select the
parameter.
Turn the rotary encoder to enter the val-
ue.
Press the rotary encoder to save the
value.
The parameters of the following functions
can be changed: